KH200D Double diagnostic table and double X-ray tube

본문 바로가기


Home > Product > KH200D Double diagnostic table and double X-ray tube
Product
KH200D Double diagnostic table and double X-ray tube
Posting date : Mar 08, 2011
Membership
Free Member Scince Mar 02, 2011
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
90-
Package & Delivery Lead Time
Detailed Description
Features: ● Double diagnostic table and double X-ray tube with rotated anode. ● KV、mA and a interlocking protection and radiograph time-limited protection devices are provided. ● Filament for stabilizing voltage, space charge compensation and anode starting-up protection device are provided. ● Voltage of power supply and kV with digital display can be adjusted constantly and respectively. ● It becomes convenient to install without above-ground railway and be operated easily. ● Electromagnetism are provided for pillar lengthways, crosswise, and sleeve moving up and down. Technology Parameters Description Technology Parameters Power Supply Voltage A.C.380V / 220V (±10%) Frequency 50Hz ± 1Hz Capacity 20KVA Power Supply Resistance A.C.380V≤1.0Ω; A.C.220V≤0.3Ω Maximum tube voltage 125KV Maximum tube currency 200mA Fluoroscopy Tube voltage 40~110KV Tube currency 0.5~5mA Radiograph Tube voltage 40~125KV Tube currency Small Focus: 25mA、50mA、100mA; Big Focus:150、200mA Spot film 100mA (Small Focus) Time 0.04~6.3s Divided into 23 grades from 0.04~6.3s High Voltage Generator Capacity 15KW X-ray Tube Model XD 51—20、40 / 125 Focus Small Focus 1×1mm2 Big Focus 2×2mm2 Rotated Speed of anode 2800r / min Diagnostic Table Scope of rotation 90°~ 0°~-5° Mobile beam filtration device Grid density N=28 Focus Distance f o>1000mm Grid Ratio r=8 Distance from surface to film ≤60mm Stomach & Intestine Radiograph Device Spot film device specification(Stomach & Intestine Radiograph) 127×178mm( 5〞× 7〞) binary picture 203×254mm( 8〞×10〞) binary picture 254×305mm(10〞×12〞) binary picture Moving lengthways (along ground railway) 1500mm Moving crosswise (left & right) 740mm Moving up and down 700mm ~ 1900mm Way of locking Electromagnetism locking Beam Limited Device Manually single automatic multi-optional Table for radiograph Length×width×height 2000×760×680(mm) Movable scope of the bed Lengthways: ±450mm; Crossways: ±110 Pillar moves lengthways 1000mm Distance from surface to film ≤60mm Bulb tube moves up and down 1100mm~1760mm Radiography item 10〞×12〞 11〞×14〞 12〞×15〞

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top