Maternal Fetal Monitor-RSD6002

본문 바로가기


Home > Product > Maternal Fetal Monitor-RSD6002
Product
Maternal Fetal Monitor-RSD6002
Posting date : Nov 11, 2010
Membership
Free Member Scince Sep 28, 2010
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
S08-
Package & Delivery Lead Time
Detailed Description
Name:Maternal Fetal Monitor Item no:RSD6002 Details: Features: 1.12.1 inch super resolution color TFT display 2. Maximum 9 waveforms 3. Use built-in system, high integrated intelligent module technology, full digital monitoring, super functions, lowest * swearing and low failure rate 4. Combined functions of maternal monitor and fetal monitor 5. Measure the intrapartum patient and fetal heart rate 6. Uterine contraction and fetal movement marker 7. Continuous real time recording of fetal heart rate 8. Can be switched to normal patient monitoring interface 9. 72 hours graphic trends and tabular of all parameters 10.1440 groups of NIBP data storage 11. ST segment 12. Anti-high frequency electronic surgical unit and anti-defibrillation, for monitoring in the surgery or for cardiac care 13.Use wide-angle, multi-wafer, wide beam and ultrasonic probes Technical Specifications: Safety IEC60601 approved (GB9706) Power source AC100V-240V, 50/60Hz Size 330mm(L) ?275mm(W) ?160mm(H) Net weight 5.0 kg Working Temperature: 5 ~ 40? Humidity <= 85% Transportation and Storage Temperature: -20 ~ 55? Humidity <= 85% Ultrasonic Probe: (Fetal Heart Rate) Type Type B proof, dirctional, using pulse doppler system Working frequency 2.5 MHz Transmitting power density 1.2m W/cm2 Probe Multi-wafer probe Sample rate 5 ms Calculating precision of FHR 0.25 bpm Accuracy of FHR 1 bpm (100-180 bpm) Marker (Fetal Movement) Manually push button mode When pressed, a red strip will be displayed above the FHR graph Uterine Contraction Pressure Type B proof Uterine contraction pressure probe Manual zero adjustment Design pressure sensitivity: 0-100% ECG Lead 5 leads (R, L, F, N, C) Lead selection I, II, III, avR, avL, avF, V Waveform 7 channels Gain selection ?. 5, ?, ? HR and alarm range Adult: 15-300bpm Neonate/pediatrics: 15-350bpm Accuracy ?% or ?bpm, whichever is greater Input impedance > 5?O Voltage range of electrode polarization ?00mV Leakage current < 30uA Filter Diagnostic mode: 0.05 ~ 100Hz Monitoring mode: 0.5 ~ 35Hz Surgical mode: 1 ~ 25Hz Scaling signal 1mV ?3% Measurement range -1.0mV ~ +1.0mV Alarm Range -0.80mV~0.80mV RESP Model RA-LL impedance Measurement range Adult: 0 ~ 120bpm Neonate/pediatrics: 1 ~ 150bpm Resolution 1rpm Accuracy ?rpm NIBP Method Automatic oscillometric Operation mode Auto/Manual Alarm Type Systolic, Diastolic, Mean Measurement ranges Systolic BP: 40 ~ 300mmHg Diastolic BP: 10 ~ 220mmHg Mean BP: 20 ~ 240mmHg Resolution 1mmHg Accuracy Max average error ?mmHg or ?%, whichever is greater Overload Protection Double safety protection SPO2 Measurement Range 0 ~ 100% Alarm range 0 ~ 100% Resolution 1% Accuracy ?% (80~100%) ?% (60~79%) PULSE RATE Range 0 ~ 254bpm Resolution 1bpm Accuracy ?bpm or ?%, whichever is greater Alarm delay time 10sec TEMP Channel 2 channels Measurement range 0~50? Alarm range 0~45? Resolution 0.1? Accuracy ?.2? Standard configuration: FHR, Uterine Contraction Pressure(TOCO), FM and Maternal ECG, NIBP, SPO2, TEMP, RESP, PULSE, Built-in rechargeable battery, thermal printe

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top