Quick Detail
Place of Origin
HS-CODE
85-
Package & Delivery Lead Time
Detailed Description
The load cell can be used in truck scale, railway scale, blending scale and special scale of all kinds of weighing apparatus. High precision and reliability. Easy installation against strong impact.
The load cell can be produced into analog load cell, digital load cell, wireless load cell, high temperature load cell.
The material: alloy steel, stainless steel
Can be use to all kinds of weighing apparatus, The load cell can be used in truck scale, railway scale, blending scale and special scale.
DescriptionCapacities (Emax)
10,20,30,40,50t.
Output:
Analog: 2.0mV /V.
Digital: 30,000 or 100,000d.
Accuracy
3000d OIML R60.
Material of load cell block:
Alloy steel o r stainless steel.
Approvals
OIML R60 C erti fica te
Accuracy class C3.
Vmin= Em ax/15000
Sealed to IEC 529.
Classification IP67 or IP68.Protection against total immersion in water for 30 minutes at a pressure corresponding to a 1 m head of water.
Model: QS Specification
Item\ Parameter C2 C3 UNIT
Rated load (Emax): 10,20,25,30,40,50,60 t
Maximal numbers of load cell verification Intervals(Nlc): 2000 3000 d
Minimum load cell verification intervals(Vmin) 0.02 0.01 % of rated l oad
Sensitivity(Cn): 2.0+/-0.1% mV/V
*Combined error: 0.027 0.015 +% o f rated output
Temperature effect on sensitivity (Tkc): 0.0024 0.0012 ⊥% of rated output/
Temperature effect on zero balance (Tk0): 0.002 0.0008 +% o f rated output/
Zero balance: 1.0 ⊥% o f rated output
Input resistance(Rlc): 775±5 Ω(O hms )
Output resistance(R0): 701±2 Ω(O hms )
Insulation resistance: ≥5000 MΩ(M ega-Ohms)
Safe overload: 150 % of rated c apability
Ultimate overload: 300 % of rated c apability
Operating temperature range: -30~+ 70/-20~+ 160 ℃/ ℉
Recommend excitation: 12 V (AC or DC)
Maximum excitation: 24 V (AC or DC)
Material of elastomer: alloy steel / stainless steel
Protection class: IP67/IP68
Citation: OIML R60 / GB7551-1997