Multiparameter Monitor--MD8000

본문 바로가기


Home > Product > Multiparameter Monitor--MD8000
Product
Multiparameter Monitor--MD8000
Posting date : Aug 23, 2010
Membership
Free Member Scince Jul 23, 2010
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
S08-
Package & Delivery Lead Time
Detailed Description
Meditech MD8000 is a 12.1" color TFT monitor, can display 7 channels ECG by one frame. It has standard parameters of ECG, NIBP, RESP, digital SPO2, TEMP and PR with optional configuration IBP, ECTO2, recorder (printer), drug dose calculation and OXYCRG. It has maximum 72 hours storage capacity and a networking ability. l 12.1 inch high brightness colorful TFT Display l Simultaneous display of 7 lead ECG by one frame l Analysis of real time ST segment and arrhythmia l Standard parameter of ECG, NIBP, RESP, digital SPO2, TEMP and PR with optional configuration IBP, ECTO2 and recorder (printer), drug dose calculation and OXYCRG l Maxi 72 hour graphic and tabular trend with data storage l Networking capacity l Digital SPO2 enables effective examination in case of active patient, low infusion and interference from electric knife ECG: lead: ⅠⅡⅢ,aVR ,aVL ,aVF ,V Gains: 5mm/mV;10mm/mV;20mm/mV;40mm/mV;auto Input impedance : ≥5M Common Mode Rejection Ratin: ≥100dB Bandwidth: 0.5—25Hz(monitoring mode) 0.05-75Hz(diagnostic mode) 1—15Hz (surgical mode) Protection: segregation breakdown Voltage 4000VAC,50/60Hz,Resistant to high-frequency etectro tome myoelectricity ,AC,drifting interference Indication of Detachment of electrodes:Available in isolation against electrosurgical interference and defibrillation Playback of cardiogram: Available Scanning speed: 25mm/s;50mm/s Heart Rate Range: 0-300BPM Accuracy: ±1BPM NIBP: Method: Oscillometry Operation modes: Manual/Automatic/STAT Measurement unit: mmHg/KPa selectable Measurement types: Systolic, Diastolic, Mean Measurement range: Adult: 10-270mmHg Over-pressure protection: YES Resolution: 1mmHg Accuracy: Mean error and standard deviation per ANSI/AAMI SP-10 Alarm: Systolic, Diastolic, Mean SpO2: Measurement range: 0-100% Accuracy: ±2digit (70~100%);0~69% unspecified Alarm range: 0-100% Respiration: Method: Oscillometry Operation modes: Manual/Automatic/STAT Measurement unit: mmHg/KPa selectable Measurement types: Systolic, Diastolic, Mean Measurement range: Adult: 10-270mmHg Temperature: Resolution: 0.1℃ Channel: Dual-channel Alarm range: 0-50℃ Options: EtCO2 , IBP , Recorder

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top