Features ■ Color TFT Screen, waveform up to 8 channels ■ Light and portable with build-in rechargeable battery ■ UP to 10 kinds of monitor parameters ■ Arrhythmia analysis, pace-marker detection and S-T Segmentanalysis ■ 72 hour storage and review of trend grams and tables, 40 second review of olographic wavefo rms. ■ Built-in recorder(option) ■ All-round monitor of adult ,pediatric and neonatal. ■ Electrosurgical unit and defibrillation protected ■ Standard parameters: ECG, NIBP, SPO2, Respiration, Temperature, Pulse rate ■ Option parameters: EtCO2, CO, IBP, Thermal Printer ECG ■ 5-lead or 3-lead selectable ■ Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C ■ Lead selection: I; II; III; avR; avL; avF; Vx; CAL ■ Gain selection: 12.5mm/s, 25mm/s, 50mm/s ■ Accuracy: ?bpm or ?%, whichever is greater ■ Protection: Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation ■ Calibration signal: 1mV?% ■ Operation modes: Diagnostic, Monitor, Surgery ■ Alarm range: Adult: 15-300bpm ■ Pediatric/Neonatal: 15-350bpm ■ Alarm range: -2.0mV~2.0mV ■ S-T detection: YES, Arrhythmia analysis: YES ■ Alarm: YES, audible and visual alarm, alarm events recallable NIBP ■ Method: Oscillometry ■ Operation modes: Manual/Automatic/STAT ■ Measurement unit: mmHg/KPa selectable ■ Measurement types: Systolic, Diastolic, Mean ■ Measurement range: Adult: 10-270mmHg ■ Over-pressure protection: YES ■ Resolution: 1mmHg ■ Accuracy: Mean error and standard deviation per ANSI/AAMI SP-10 ■ Alarm: Systolic,Diastolic,Mean SpO2 ■ Measurement range: 0-100% ■ Accuracy: ?digit (70~100%); ■ 0~69% unspecified ■ Alarm range: 0-100% Respiration ■ Method: RA-LL impedance ■ Pediatric/Neonatal: 6-150rpm ■ Alarm range: Adult: 6-120rpm ■ Pediatric/Neonatal: 6-150rpm ■ Apnea alarm: YES Temperature ■ Resolution: 0.1℃ ■ Channel: Dual-channel ■ Alarm range: 0-50℃ Option: EtCO2 ■ Measurement Mode: Side-stream or mainstream ■ Measurement range: EtCO2: 0-99mmHg ■ Accuracy: CO2 concentration ■ Apnea alarm: YES CO ■ Method: Thermo-dilution ■ Measurement range: CO: 0.1-20 lit./min. IBP ■ Channel: 2 channels ■ Pressure transducer: Sensitivity: 5( mV/V/mmHg) ■ Transducer sites: ART, PA, CVP, RAP, LAP, ICP ■ Alarm range: -10~300mmHg

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top