pulse oximeter

본문 바로가기


Home > Product > pulse oximeter
Product
pulse oximeter
Posting date : Jul 01, 2010
Membership
Free Member Scince Jul 01, 2010
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
90-
Package & Delivery Lead Time
Detailed Description
CMS 50H Pulse Fingertip oximeter Ultra-thin design ,concise fashion Low power alarm,probe-off alarm,overrun alarm adjustable. Inner flash memory for 24 hours storage,and upload to PC. The display direction can be changed automatically,easy to view. PI detection:blood stream perfusion index. CMS50H pulse oximeter is a portable oxygen and pulse rate detection equipment, applies to health care sites, families,Oxygen Bar and medical institutions for oxygen and pulse rate detection. The main features are as follows: 1.Pulse rate value display, bar graph display 2.Pulse waveform display 3.Perfusion Index value display 4.Charge function: Lithium battery is the power supply and can be charged up time and again. 5.Low-power indication: low-power indication symbol appears before working abnormally which is due to low-power. 6. Automatic power-off when there is no finger in device under measure interface in 5 seconds. 7. With direction sensor,the display direction can be changed by automatic or manual mode 8. Screen brightness can be adjusted 9.Pulse sound indication 10.With alarm function 11. With SpO2 value and pulse rate value record function 12.The record data can be uploaded to the computer 13. It can be connected with oximeter probe Display Type: 65K color OLED display Parameters:SpO2, PR, PI,Pulse bar Mode: 4 display modes Brightness :Adjustable 4 levels Technical specifications Measurement of SpO2 Measuring range: 0% to100% Accuracy: When the SpO2 measuring range is 70% to 100%,the permission of absolute error is ±2 Below 70% unspecified Measurement of pulse rate Measuring range:30bpm TO 250bpm Accuracy: ±2 bpm or ±2% (select larger) Resolution SpO2 : 1%, Pulse rate: 1bpm. Measurement Performance in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger). Resistance to surrounding light The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%. Storage Environment a) Temperature :-40+60'C b) Relative humidity :5%-95% c) Atmospheric pressure :500hPa-1060hPa Operating Environment a) Temperature:10C-40C b) Relative Humidity :30%-75% c) Atmospheric pressure:700hPa to 1060hPa Dimensions:58(L) × 36(W) × 26(H) mm Weight:About 45g (with a lithium battery) Battery RequirementVoltage 3.7 rechargeable lithium battery Power supply requirement: : 3.6 V DC ~ 4.2V DC.

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top