patient monitor

본문 바로가기


Home > Product > patient monitor
Product
patient monitor
Posting date : May 20, 2010
Membership
Free Member Scince May 20, 2010
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
90-
Package & Delivery Lead Time
Detailed Description
Features: 1. Single or Twins Ultrasound transducer 2.Data Graph and Trend Table Review of both mother and fetal 3.Built-in thermal printer 4.Built-in Network capability for connect with central monitoring software 5. Programmable alarms 6.All the colors and looks or the parameters can be customsized 7.Multi-face views, select focus on mother or fetal 8. Storage of patient information and data Performance Specifications: 1. Display:8.4" Color TFT 2.Resolution:640x480 3. Display Mode:Standard View,Fetal View,Mother View 4. Indicator:Power indicator light, Alarm sound 5. Interface:Socket for connecting fetal's FHR, TOCO, and Fetal Movement sensorSocket for connecting mother's ECG, NIBP and SPO2 sensor. Net Socket(RJ45) for communication cable with Central Monitoring Station Sofrware. 6.Power Supply:AC 100 ~ 240V, 50/60Hz, Powe < 60VA 7. Trend Graph:Resolution from 1s, 5s, 10s. Maximum time 96 hours. 8.Trend Table:Resolution from 1s, 5s, 10s. Review up to 1000 items. 9. Alarm:Ajustable High and Low limits. Three level au dible and vistual alarm. 10. User Configuration:All the color of parameters and waves can be set according to user's willing. Technical specifications: 1.Safety 2. Meet the requirment of IEC60601 series 3. Type of Protection:Class II with internal electirc power supply 4. Degree of Protection:BF 5. Dimention and Weight 6. Dimention:92(W)x82(H)x22(D)mm 7. Weight:136g(with battery) 8.peration Environment: 9.Temperature:0℃~ +40℃ 10.umidity:15% ~ 95% 11.torage Environment: 12.emperature:-20℃~ +60℃ 13.umidity:10% ~ 95% 14.tient Range:Pregnant Adult FHR: 1.Ultrasound Frequency:2MHz 2.Range:50 ~ 210 bpm 3.Resolution:1bmp 4.ccuracy:±2bmp TOCO: 1.ange:0 ~ 100% 2.Resolution:1% 3.Non-linear Error:<=±8% 4.ero control:Manual FETAL MOVEMENT: 1.anual fetal movement mark SPO2: 1.Measurement Range:0 ~ 100% 2.Resolution:1% 3.ccuracy:±2%(70%~100%, Adult/Pediatric, non-motion) ±3%(70%~100%, Neonate, non- motion)0% ~ 69% unspecified 4.Alarm Range:0% ~ 100% 5.Refreshing Rate:1s Pulse Rate: 1.easurement Range:25 ~ 250 bpm 2.solution:1bpm 3.Accuracy:±3 bpm (non-motion) 4.Alarm Range:25 ~ 250 bmp 5.efreshing Rate:1s ECG: 1.ead mode:3-lead or 5-lead 2.Lead selection:I, II, III, AVR, AVL, AVF, V 3.HR range:15 ~ 300 bpm 4.ECG Waveform:2 channals 5.ccuracy:±2bpm or ±2%, which is greater 6.S-T segment detection range: -2.0mv ~ +2.0mv 7.Arrhythmia analysis: 13 kinds of arrhythmia 8.larm Range:15 ~ 300 bpm NIBP: 1.Method:Oscillometry 2.Mode:Manual/Auto/Contiuous 3.Measurement Range:25 ~ 260mmHg 4.Atuo Measure Interval: 5, 10, 15, 30, 45, 60, 90 minutes 5.Resolution:1mmHg 6.Overpressure Protection: 300mmHg 7.Alarm range:25 ~260mmHg

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top