XYJZF Series Piston Type Multi-medium Angle Seat Valve
Feature:
1.External pneumatic guide may prolong the service life and is free of maintenance.
2.The self-adjusting gland between the overflow port and slide block may improve the
sealing performance.
3.The angle seat structure of the valve may realize big flow (especially compared with
general stop valves) with compact structure and quick response.
4.Medium Temperature: -10~+180℃
Technology Parameter
Model Joint Pipe
screw thread Kv
Value Max.Pressure Resistance Min.pressure
Resistance Performe Size(mm) direction
of flow
polyamide Aluminum
alloy
XYJZF-15 G1/2” 4.2 0~1.6 0.39 50 — A
OR
B
XYJZF-20 G3/4” 8 0~1.1 0.39 50 —
XYJZF-25 G1” 19 0~1.1 0.42 63 —
XYJZF-32 G11/4” 27.5 0~1.5 0.5 63 100
XYJZF-40 G11/2” 42 0~1.25 0.44 63 100
XYJZF-50 G2” 55 0~1.0 0.4 — 125
Installation & Maintenance:
It is required to follow suitable safety regulations:
1. The pipeline should be clean without pollution.
2. To be installed as required. But it is preferred to make the executing unit face upward.
Pay attention to flow direction.
3. When connecting the valves, be sure to aim at the pipe. Only with special requirement
of the user can the executing unit be taken down.
Before opening or repairing the angle seat valve, cut off the flow and control air source
and lower the pressure in the pipeline system.
Notice:
Characters for selecting flow direction A:
1. When selecting such flow direction, the service life the product can be prolonged.
2. When the working medium is liquid, selection of such flow direction may prevent
impact by water hammer.
For products with diameter of φ15, φ20 and φ25, the working pressure
should be below 0.3MPa. Otherwise, you should choose to use double acting executors.
For products with diameter of φ32 and φ40, you must choose double acting type with
size ofφ100.
For products with diameter of φ50, you must choose double acting type with size ofφ125.
Characters for selecting flow direction B:
When the working medium is steam or gas, if you choose such flow direction, you may
improve the fluid sealing performance of the products. However, as the V-seal ring in
the valve long time contacts working medium, it will force certain affect on the service
life of the products. Besides, when the working medium is liquid, there’s no prevention