TKR-400High-frequency Mutil-functional Ventilator

본문 바로가기


Home > Product > TKR-400High-frequency Mutil-functional Ventilator
Product
TKR-400High-frequency Mutil-functional Ventilator
Posting date : Jun 16, 2009
Membership
Free Member Scince Jun 08, 2009
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
90-
Package & Delivery Lead Time
Detailed Description
Feature: A. HFJV (High-frequency jet ventilation) with pressure support, which can supply a higher inspiratory pressure so that the patients can aspirate sufficient oxygen easily. B. Opening airway. The ventilation can be made with high frequency and little tidal volume and low airway pressure, which is beneficial to increase the blood oxygen density. C. Ventilation mode through nasal vestibule non-invasive which can avoid from tracheotomy and endotracheal tube so as to reduce patient's pain and the effectiveness of oxygen feeding is very good, the patient can talk, drink and eat, when ventilating. D. Continuous positive airway pressure with adjustable oxygen concentration plus effective humidifier can make the feature of CPAP better. E. Adopted digital display screen, which displays all parameters accurately and improves the performance and accuracy of the ventilator. F. The multi-functional humidifier adaptor can be connected with any type of humidifier by trachea intubation with national or international standard. G. The pressure humidifier has switch to manipulate the air volume and has the delicacy alarm with sound and light for no power or gas. Specifications:  Frequency: 10~150 breaths/min  I/E ratio: 1 : 1~ 1 : 4 and inverse ratio Humidifying rate: No less than 15ml/h  Process Ventilation: T=10min, I/E=1: 1.5 ProI:  f(150): f(15)=7: 3 ProII:  f(15): f(150)=7: 3  SIGH: 6 breaths/min  Alarm: Alarm with light and sound for no power or no gas for 6 seconds.  CPAP: 0.1kPa~0.8Kpa  PEEP: 0.1kPa~0.5kPa  Maximum Oxygen Concentration: 85%  Alarm for upper-limitation of airway pressure: Three conditions: 0.5KPa, 1.0Kpa, 2.0Kpa  Pressure Regulator Limit: 0. 3MPa  Ventilation Mode: HFJV(High Frequency Jet Ventilation);CPAP(Continuous positive airway pressure);ProI and ProII ventilations; HFJV+SIGH, HFJV+PEEP and Manual ventilation.

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top