Infant Incubator

본문 바로가기


Home > Product > Infant Incubator
Product
Infant Incubator
Posting date : Mar 04, 2009
Membership
Free Member Scince Mar 04, 2009
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
90-
Package & Delivery Lead Time
Detailed Description
II-1000 Series Infant Incubator • Standrad configuration: High performance microcomputer control; touch film key operation; constant temperature cover with inclined plane; two display screens for set temp, box inner temp; >37℃ set-up; set-off memory; warning for: set-off, fan, sensor, over box inner temp. & temp. deviation; warning silencing function, self-test; wall cupboard and shelf and RS-232 or 485 connector. II-1000YC • Standard configuration + Infant bed adjusted with stepless. II-1000CM • Standard configuration + Side door for operation, such as injecting to infant scalp. II-1000SC • Standard configuration + Dual air curtains. II-1000GL • Standard configuration + Phototherapy(blue light)unit, LED display timer, display treatment time and total time. II-1000SGL • Standard configuration + Two phototherapy(blue light)unit, LED display timer, display treatment time and total time. Specifications: • Power Supply: AC 110/220V±10%, 50/60Hz±2% • Heating Power: ≤400VA • Convenience Outlets: AC 110/220V±10%, 50/60Hz±2% • With respect to IEC601-1, this equipment is Class I, Type B • Continuous operation with short time loading(VHA) Alarms: 1. Power Alarm • Power failure: Activates if primary power to the incubator fails or the power code is accidentally disconnected from the wall receptacle. 2. Fan Alarm • Fan failure: Activate if fan electromotor failure or fan power failure, or fan rotate speed below 1,000 turn/min because of outside force. 3. Sensor Alarm • Air sensor failed: Air sensor malfunction. • Sensor failure: Air sensor not connected to the incubator. 4. Deviation Alarm • High air temperature: Activated if displayed air temperature is 1.5℃ above set point. • Low air temperature: Activated if displayed air temperature is 2.5℃ below set point. 5. Over Temperature Alarm • Over air temperature: Activated if incubator temperature arrived 38℃ for set temps <37℃ in Air Mode; arrived 40℃ for set temps >37℃ in Air Mode. Silence function of “▲/Silence Complex Key” The “▲/Silence Complex Key” can make following alarm silenced for 15 minutes. • Deviation Alarm • Sensor Alarm • Fan Alarm

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top