Specifications:
Ball valve, check valve: brass material
Maximum self consumption: ≤3W
Accuracy of temperature measuring: ±1
Externality size: 450 x 310 x 150mm
Range of temperature measuring:
NTC: 0 to 99°C
PT1000: 0 to 199°C
Power of circulation pumps (temperature difference circulation pump, water-using end circulation pump): 600W
Electric power: ≤3,000W
Selectable power: ≤6,000W
System working pressure 8 bar and safety valve response pressure 6 bar
Input signal: 3 temperature sensors (for top of tank, for heat collector, for bottom of tank)
Output signal: 3 (auxiliary heating, temperature difference circulation pump and water-using end circulation pump)
Certificate: CE
Packing: carton
Components:
Safety valve: protects system components against excessive over-pressure in all operating phases
WILO pump: this pump is a standard device in the system and that required operating point can be preselected using one of the three levels
Manometer: hydraulic pressure manometer with a range from 0 to 10 bar indicates system pressure
Connect of expansion vessel: insert expansion vessel, avoid the system working at minus pressure
Flow sensor: timely monitor medium flow rate of the whole system
Heat preservation material: EPS
Screw thread: 1/2-inch
Maximum working temperature of pipeline: 110°C