Main performances and features
Hi-accuracy synchronizer realizing conquer some defaults such as low accuracy, serous disturbance, temperature drift, cost, unfitting for the complex topography and so on.
It apply an IGBT bridge circuit to the lightweight transmitter so that works efficiently, switches power on and off over a nighttime. Techniques as floating point amplifier and FPGA are used in high-resolution receiver as to set up a portable system fitting for the complex geological environment in geophysics and engineering exploration. This system is extensively applying to mineral investigation, engineering exploration, water resource survey, and environmental polluting examination at present.
Features
Eternal connecting to PC
logging can be made upward and downward
Digital and analogue signals to be received.
Winch will stop automatically when it arrive the ending depth
Auto-sampling according to the depth interval
Simulation logging indoors to observe the repeatability of the instrument and probes
Depth control and data acquisition system by integration
Real-time display the supply voltage frequency and magnitude of voltage
Real-time display the working voltage and current of the borehole probes
Filmed panel for a long time
Specifications
12-bit A/D converter, enlargement factor k range from 0.5 to 128
Counting channel frequency: f ≦500KHz.
Digital signals transfer frequency 9600bit/s
Power-off delay: 1 to 9999ms (optional)
Depth measuring error: ≤0.4‰
Logging speed: 0.5 to 30 meter/min (adjustable and in relation to sampling interval)
Power consumption: less than 1.5 KW
Dimensions: 480×280×230mm; Weight: less than 10 kg
Input range of analog signals: ≤±10V
Supply current: 1mA to 500mA (optional)
Power-on time: 1 to 99s (optional)
Sampling interval: 1 to 9999ms (optional)
Displays range of depth: 0 to 9999.99 m
Operable temp. range: -10℃ to +50℃
Power supply: AC220V±10% 50Hz±5%
Logging system software
Operation system: windows98/2000/XP
Sampling interval: 1cm to 1000cm
The max depth of collecting once is 3000 meters (0.1 meter sampling interval)
Multi-parameter auto-aligns depths.
Multi-parameters (curves) stacks and the number can be up to 10.
Curve drift, anomaly remove, smoothness, inverse the orderings, combination, segmentation, computation and so on.
Interpreting sections input and rock-formation name, thickness, bottom block depth will automatically produce out.
Curve scaled (zoom in or out).
Curve depth scales, five kinds: scales of 1:50,1:100, 1:200, 1:500 and 1:1000
Colored or Grey plot maps.
Output map’s max-width 415mm, length 2310mm.