Quick Detail
Place of Origin
HS-CODE
82-
Package & Delivery Lead Time
Detailed Description
Features
Exploration of high resolution and high efficiency resistivity measurement
The system consists of two parts, one is multi-function DC resisitivitymeter and the other is multiplexor (Ⅱ). It uses to explore matching with the high-new techniques such as CT and automation of electrodes converting to measure and supply, based on the theory of regular resisitivity methods.
Time domain DC resisitivity method and IP method
Multi-function DC resistivitymeter DZD-6A can solely employ to measurement and that it realizes resisitivity method and IP method under the conventional mode. And this method possesses plenty of measuring parameters: Spontaneous Potential Vsp, primary field potential Vp, supply current I, apparent resisitivity RO(ps), apparent polarizablility M1-6, half-life time Th, degree of damping D, synthetic excited electron parameter Zp and degree of deviation R.
Flexible and convenient operations
This instrument can auto-compensate the cases of self-potential, drifting and polarized electrodes by employing a full digital auto-measurement. And the result displays on a large LCD screen which can list a total 14 kinds of method models under the High-Density measurement. At the meantime, the sole DZD-6A measurement has 9 kinds of electrode arrangements and real-time display the measured curves.
Convenient data translation
a. One time can store data is up to 120000 under the model of high-density measurement.
b. One time can store total 4800 of sounding points and profiles under the model of sole instrument of DZD-6A, of which one point includes 22 data. This data can be transmit to a PC to digitized-translate them by their corresponding software.
Available accessories:
The 60/120 channel-detector
The copper electrode with spikes
Extended temperature cables
The overburdened lines.
Main specifications
DZD-6 Amulti-function DC electric resistivitymeter
Measured maximum voltage: -6000mV ~ +6000mV
Measured voltage resolution: 0.01mV
Measured voltage accuracy: ±1%±1LSB
Notch filter to 50HZ is superior to 80dB
Measured current: 0~5000mA
Measured current resolution: 0.01mA
Measured current accuracy: ±1%±1LSB
Input impedance more than 30MΩ
Transmitter
Maximum voltage of supply: 900V
Maximum current of supply: 5A
Power supply pulse width: 1~59 sec. Take-up to blank ratio is 1:1
Multiplexor
Total electrodes used for shifting is 60 or 120.
Spacing and interval factor are determined by your work state.
Maximum current: 2.5 A
Endurable voltage: 500 VDC
Isolation performance: 500MΩ
Operating temp: -10℃~+50 ℃
Operating moisture: 95%
Work temperature: -10℃--50℃
Power: +12V
Record format: SEG-2
High-rank armed engineering controller, hard-disk 40GB; write panel, touching keyboard; high-resolution TFT colored LCD screen; interface: standard interface configuration
Software: reflection, refraction, surface wave, shear wave processing Software wrap; reflection, refraction, surface wave, pulse, image, wave-velocity blast, stake detect acquisition software