Quick Detail
Place of Origin
HS-CODE
82-
Package & Delivery Lead Time
Detailed Description
Applications
Investigations of depth minerals and geology survey in a large area with high efficiency and good convenience. Extensively employ to exploration of ground water, mineral resources such as metal minerals and non-metal resource and engineering exploration
Features
The system includes a transmitter, a power rectifier and a recerver.
PC control and large LCD display,touch key panel and RS-232 interface
High voltage ,heavy current ,with overvoltage and overcurrent protection
Using special miniature transformer,lightweight.
Specifications
Transmitter (DJF–10)
Input voltage: 200V50Hz AC power supply;
Output voltage: 50V, 100V, 200V, 300V, 400V, 500V and 1000V;
Output waveform with ratio 1:1;
Time: available between 1 and 60 seconds;
Max current supply: 7/10A;
Max output power efficiency: 5/10 Kw
Operating temp: -10℃ ~ +50℃
DJS-8 Receiver
Measuring voltage maximum: ±3V
Measuring voltage resolution: 0.01mV
Measuring voltage accuracy: ±1%±1LSB
Current accuracy: ±1%±1LSB
One startup can get the values of a Vp and four Ms, and their width ratio is 1:2:4:8
Power supply interval: 4, 8 and 16 seconds
Polarizablity measurement accuracy: When Ms is less than 3%, the accuracy is ±0.2±1LSB ; when it more than 3%, it is 0.2±1LSB
Repeat measuring times: available 1—10 times
Instrument delay time: 100ms –1000ms
The notch filter is superior to 80dB
Input impedance: more than 30 MΩ
Data storage: 128kB
Run environment temperature: -10℃~+50℃, humidity: 95%
Dimensions: 240X95X240 mm