fingertip pulse oximeter

본문 바로가기


Home > Product > fingertip pulse oximeter
Product
fingertip pulse oximeter
Posting date : May 26, 2008
Membership
Free Member Scince May 26, 2008
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
90-
Package & Delivery Lead Time
Detailed Description
 Fingertip oximeter            Product Properties: 1.Operation of the product is simple ang convenient. 2.The product is small in volume,light in weight(total weight is about 50g including batteries)and convenient in carrying. 3.Power consumption of the product is low and the two originally-equipped two AAA batteries can be operated continuously for 30 hour. 4.Low voltage warning will be indicated in visual window when battery voltage is so low that normal operation the Oximeter might be inflluenced. 5.The product will automatically be powered off when no signal is in the product for more than 8 seconds. Product Operation Scope The fingertip Oximeter can be used to measure human Hemoglobin Saturation and heat through finger.The product is suitable for use in family,hospital(including clinical use in internist/surgery,Anesthesia,pediatrics,intensive care and etc),Oxygen Bar,social medical organizations,physical care in sports(it can be used before or after sports.continually monitoring is not recommended). Technical Parameters:  Display Format:  LED  SPO2:  35-99% in two-digit 7-segment digital  Pulse Ratio:  30-240 BPM in 3-digit 7-segment digital  Pulse Wave:  6-segment bargraph  Battery Voltage Low Indication:  LED signals  Power Requirements:  Two AAA size 1.5v Alkali Battery  Power Consumption:  Less than 40mA  Resolution:  ±1% for SP02 and ±1 BPM for Pulse Ratio  Measurement Accuracy:  ±2% in stage of 70%-99% SP02 and meaningless when stage being smaller than 70%.±2 BPM for Pulse Ratio  Measurement Performance in Weak Filling Condition:  Oxyhemoglobin and pulse value can be shown correctly when pulse-filling ratio is 0.5%  Interference Resistance Capacity against Ambient Light:  Deviation is smaller thasn ±1% between value of Oxyhemoglobin measured in natural lighting indoor condition and present lighting sources and that measured in dark room  Automatically powered off:  No finger is in the Oximeter more than 8 seconds.  Size:  56x31x33mm

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top