Model:W 253566
Constant chemistry test 360 / hour, up to 600 tests / hour (with ISE)
Reagent arms system, three independent arm, three three-needle arm
Reagent refrigeration function
Level sensor probe and VOD protection
Permanent color quartz glass cups, reduce wear and tear
Colorimetric reaction of the cleaning function Cup
Double needle spiral agitator
Emergency priority testing samples
After the grating by technology, wavelength selection 12
WINDOWS interface, Chinese reporting system
True vertical system
Water is low and only 5 per hour L deionized water
Specifications
Test speed: 360 tests constant speed / h, the biggest test 600 / hour (including ISE).
Determination: 50 (with ISE53).
Analysis: destination, speed, 2:00, electrode (optional)
Samples of 1-20-60 μ l (0.1 μ l Step).
Reagent of :10-300 μ l (0.1 μ l Stepping)
Reaction solution volume :150-360 μ l.
Sample disk: 80-bit samples can be in full bloom 5,7,10 ml tube and the general sample cup.
Emergency specimens: 25-bit emergency.
Reagent disk: 50-reagent, all of a frozen function.
Reagent Bottle: 5 ml, 20ml, 50ml multiple specifications choice.
Storage projects: 99 projects parameters, or superscript 10 projects, three projects ISE (optional).
Response curve: real-time response curve, a total of 51 readings point (8.5 minutes).
Cup Reaction: 60 permanent quartz glass color cups, washing machines, optical 6 mm diameter
Reaction temperature: 37 ℃ +/- 0.1 ℃
Optical system: by grating after 12 optional wavelengths (340-800 nm), single-and dual-wavelength setting
Absorbance range 0-3.5 OD, colorimetric measurement Direct Reading Cup.
Source: Halogen, 12 V, 20W
Data Processing: 12 kinds of imitation-like curves, data retrieval, data editing, quality control management, and multi-point calibration, serum information, incremental sample, sample reduction, the project operation, re-dilution test, calibration curve, detection reagents cushion, blank detection, response real-time monitoring, pre-mix - R management, and quality control of dual-emergency functions.
Water: only 5 L per hour, no water treatment device
Network Interface: Two-way Interface RS232C
Power requirements: AC220 +/- 5V power 1.1 KVA
Dimensions: 840 (W) * 610 (D) * 110 (H) mm
Weight: about 160 kg
XL_300 sound quality control procedures
* Provide quality control procedures levy_jenning round
* Show daily monthly quality control results
* Two graphical format, the unique double-quality control plans and - R management
* Automatic quality control procedures
* The double-decker design
* Regular testing of the outer-50
* Lining 32 quality control standards set (also available to emergency samples)
* 20-bit standard
* 8-bit quality control
* 2-blank, 2-ISE Calibration
* 5ml 7ml 10ml quality of the samples before