Ozone Generator (in the air)

본문 바로가기


Home > Product > Ozone Generator (in the air)
Product
Ozone Generator (in the air)
Posting date : Mar 06, 2008
Membership
Free Member Scince Mar 06, 2008
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
29-
Package & Delivery Lead Time
Detailed Description
Model: QX50SJ-B-3F First, the computer technology performance parameters: Rated working conditions: air-drying system to deal with dew point ≤ -45 ℃, cooling water temperature ≤ 20 ℃ Ozone production: Ozone 30 g / h concentrations of ozone: 8-10MG / M ³ Water dissolved ozone concentration: ≥ 0.3 mg / L gas source: no oil compressor 0.06 / 2 specifications Power: Ac220V ± 10% 50HZ 5A power consumption: ≤ 18 KH/KgO3 Weight: 33 Kg size: 450 × 350 × 1100mm3 Second, the installation 1, machines are usually installed in the ventilation, dry, clean and place above room temperature greater than zero (special design otherwise), should not have machines around flammable and explosive materials (such as flammable gases, etc.). 2, Warning! ! ! : In order to personal safety, install three Plug Power Line (FireWire, zero line, earth), the single-phase power supply voltage of 220 V ± 10% (over this value must be the installation of a voltage regulator, to avoid mechanical failures), while grounding line for machines Good (grounding resistance must be less than 4 ohms). 3, in accordance with the requirements of good-effectively access, drainage, trachea. 4, ozone exports to ozone resistant tube (a PVC material such as stainless steel), when the attention of the installation of a one-way water protection measures to prevent water intrusion into the ozone generator damaged machines. 3, operation 1, machines operating system: As automated computer process control, without personal care, fault self-inspection, self-exclusion, special circumstances emergency installations to ensure normal operation of equipment is not missed production. Users also very simple, just plugged in, according to the need for better computer control procedures, all the work done automatically by computer, or their own sterilization, automatic shutdown, automatic standby, automatic detection, automatic access emergency system and ensure the completion of work tasks. 2, a computer control and operation characteristics: Features: a high-power direct control of six kilowatts; b daily walking error is less than 0.5 seconds; c afraid power, the internal rechargeable automatic; d can be set up to a day six times a related action, and 6; e installed and tested convenience; f switch cycle time can be days or a week cycle control g longest time 168 hours, the shortest time to control one minute. Timing settings: a transfer clock: (good for the factory has been re-adjusted if necessary) Hold down the "clock" button at the same time cling to click the "school week" button, the "school" button and the "school-" button. The first set opened B: Click the "regular" button, a liquid crystal display, and click the "school" button and the "school-" button, enter the first open time. C closed the first set: click the "regular" button, a liquid crystal display (Figure 2), and click the "school" button and the "school-" button, enter the first closing time. D to continue to push the "regular" button, the screen showed the name in the list will be followed by (2 on, 2off…… 6 on 6 off), the reference to steps b and c, after all, set up the opening and clearing time. If only a day and a clearance, it must be a "cancel / restore" button, (2 on, 2off…… 6 on 6 off) to eliminate the storage time, the liquid crystal display a "----" drawings. E regularly based system completed, should be "clock" button displayed on the LCD screen SGT. F connect power, the panel said that the red-circuit and electricity, traffic lights at the same time - that switch is. Activated G "Auto / Manual" button, and can be opened directly by the Commissioner circuit. Automatically switch to let action, should please press the "Auto / Manual" button will display a short horizontal line transferred to the "off" position, and then click the button transferred to the "automatic" position. For example, "Every day 18:30 open automatically set in accordance with the above b daily 23:20 c shut down automatically in accordance with the above set. D by the following debugging on the LCD (2 on, 2off…… 6 on 6 off ) showed "----" drawings, and then e, f, g operation. by H "regular" button, according to the "week" button, the same can be set every day, and different every day, Monday to Friday the same as Saturday to Sunday the same settings. 4, maintenance 1, dryer maintenance: To ensure that machines work in the dry state low dew point, it should be noted oxygen-rich dry (in the oven at 300 ℃ -350 ℃ drying temperatures can be 3-4 hours, after drying home cooler particles can be desiccant repeatedly re-use. 2, in the total supply of electricity premise, the application of the soft brush dry cleaner machines, more regular cleaning of electronic circuit boards and dust surrounding environment, so as to avoid any adverse impact on the machine. 3, machines can not be normal electricity, please cut off the power supply to see whether the chassis side power fuses good contacts or links, please replace the same number of models amp fuse. If the machine is a telegram Fuse Fuse, the most ozone-frequency circuit boards for electronic components or damage to a high-voltage discharge room humidity condensed water there, information professionals are invited to inspect and repair. 4, no long-term winter, and should be condenser cooling water discharge emptying rooms so Donglie mechanical. 5, warning! ! ! : In order to personal security, electricity is prohibited in the state, opening the door ozone generator in order to avoid electric shock injuries. Boot to be locked doors, keys custody by qualified electricians specialized, non-machine operators to prohibit contact with machines to avoid accidents. 6, Attention! ! ! : Ozone generator power should be auto regulator, the voltage raised to 180 V ~ 190V. 7, ozone disinfection 40 minutes each time 8, the outer surface cleaning equipment can not be wet cloth, use a dry cloth to wipe clean.

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top