TCP-600 Light duty vehicles Emission Measurement Equipment

본문 바로가기


Home > Product > TCP-600 Light duty vehicles Emission Measurement Equipment
Product
TCP-600 Light duty vehicles Emission Measurement Equipment
Posting date : Feb 27, 2008
Membership
Free Member Scince Feb 27, 2008
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
87-
Package & Delivery Lead Time
Detailed Description
TCP-600 Light duty vehicles Emission Measurement Equipment C&P has developed TCP-600 Light duty vehicles Emission Measurement Equipment,with the tech. supported by TianJin University. It reaches international advanced level. It includes CFV-CVS unit、 Analyzer unit, of gases emission from SI engine and CI engine. CI engine particulate emission and HC gas analyzer, computer control unit and dyna-mometer. We also can offer ambient test cell when vehicles would be test after a cold start at the low ambient temperature. C&P have been cooperating with CAI(USA). ETC(USA). Real-Time(USA) and Signal(UK) for developing advanced emission system.TCP-600 light duty vehicles emission measurement equipment can meet the requirement of vehicle EC type-approval certification and the examina- tion production Conformity in Automotive industry. This product meets the following standards: 1. GB18352.3-2005: Limits and measurement methods for emission from light duty vehicles (china). 2. (70/220/EEC (98/69/EC): European Community rules of light duty vehicles emission. 3.40 CFR part 86: EPA(USA) rules of vehicles emission. CFV-CVS Unit: The CVS unit has reasonable design, beautiful outlook, perfect functions, and good stability and reliability. Precision of equipment: measuring deviations is less than 3% by CFC method or less than 3% by gravimetric technique. Analyzer Unit: We adopt the analyzer 600 supplied by CAI company. It has the following features: 1 .Digital communication 2.High precision 3.Reliable and steady capability 4.Selecting range according to your need. 5.Adjusting zero by programme automatically or manual. 6 .To meet the requirement of standard of china (GB) and EC standard completely. Measuring Particulate and HC Emission From CI engine : ( 一) Measuring particulate emission is an important part of light diesel duty vehicles emission test system..It include HFID Analyzer with recorder, heated-pipeline, dilution channels, filter, sampling detector and flow regulator, etc. ( 二 ) Parameter of main component: 1 .CFV(critical flow Venturi) volume flow(standard condition) lO and l2 m/min, precision 0.3%. 2.Heated FID (HFID) Model 600: allowed ambient temperature 473K ± 10K (200~C ± 10~C). 3.Responsive time of sampling system is no more than 4s. 4.Filter paper standard: orifice diameter 0.1 vm, diameter ~~47mm. 5 Weighing chamber standard (option): temperature 298K ± 6K, relative humidity 40% ± 10%, a pair of balances precision 0.1mg TCP-600 adds a direct sampling interface. We can add the Analyzer Unit to meet the specifications of customer. Center Control Unit: The control software is developed by C&P.We achieve automatic control by computer. Features of the system as follows: 1 .To meet China National Standard (GB), EC and America EPA. 2. Comprehensive function. 3.Fast and smart operation. 4.Perfect system. 5.Fully Automatic control operation. 6.Humanization. beautiful and friendly interface. Chassis dynamometer: We cooperate with America REALTIME company and produce the chassis dyna-mometers that are suitable for the vehicles driren by front,back or all. ( 一 ) Main characteristics: 1. Digital adjustment. Speed is attained by a high precision digital impulser. 2. Inertia simulation and road simulation. 3. Perfect security protection. 4. Perfect monitor and control functions. 5. Perfect functions, friendly and graphic human machine interface, and convenient operation of control software. The part that tests granule and HC gas which CI engine emited ( 二 ) Main parameter: 1 Diameter of barrel roll 12192+/-0.1 mm 2 Maximum allowable axle mass 2000kg 3 Maximum test speed 200 km/h 4 Range of inertia simulation 454~ 2722 kg 5 Maximum invariableness drag power 147kW ( speed>lO7 km/h ) 6 Maximum drag power 208kW ( speed > 107 km/h ) Ambient test cell To meet the requirement of GB18352.3-2005(standard of china) and 98/69EC. 1. Scale of ambient test cell: about 15m*am*6m* (L*W*H). 2. Ambient temperature, humidity and pressure adjusted, controlled, and printed automatically. ①Range of ambient temperature controlled: -10~C~40~C (option:-40~C~60~C). ② Range of ambient humidity controlled automatically: 5.5 ~12.2 g/kg, 3. According to user' s specification ,we can offer lamination devices that can simulate sun radiant intensity and heating carpet devices( maximum temperature can reach 20~C~75~C) that simulate hot road.

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top