Nettest CMA4000i Optical Test System

본문 바로가기


Home > Product > Nettest CMA4000i Optical Test System
Product
Nettest CMA4000i Optical Test System
Posting date : Nov 17, 2007
Membership
Free Member Scince Nov 17, 2007
Keyword :
Category
Contact
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
HS-CODE
90-
Package & Delivery Lead Time
Detailed Description
CMA4000i Optical Test System The CMA4000i Optical Test System is an all-in-one test and measurement solution for network commissioning, fault location/restoration, maintenance, and DWDM spectral analysis. Combining best in class OTDR and OSA performance, modular flexibility and ease-of-use, the CMA4000i is the ultimate time saving system for increasing network performance while reducing the cost of measurement. Mainframe Specifications Display VGA LCD Display (21.3 cm (8.4 inch) color or 20.8 cm (8.2 inch) monochrome) Floppy Drive 3.5 inch/1.44 MB floppy disk (up to 180 OTDR traces for a standard disk) Keyboard Intergral alpha-numeric, external keyboard (optional) I/O Ports Standard: (2) RS-232 Serial, (1) Parallel, VGA, Mouse, and (1) PS/2 External Keyboard Port Internal Storage Up to 125 OTDR traces internal 2 Gigabytes minimum (Over 65,000 traces with hard drive option) Dimensions (H x W x D) 24.1 x 34.3 x 9.5 cm (9.5 x 13.5 x 3.75 inches) Weight 4.9 kg (11.0 lbs.) Includes mainframe, battery and module Power Supply Autoswitching 100-132 VAC, 47-63 Hz, 184-250 VAC, 47-63 Hz, 10-15 VDC Battery (2) Sealed lead acid battery pack Battery Life 6 hours typical, depending on operating mode Recharge Time 1.5 - 2 hours AC Power Temperature 0o C to 45o C (32o F to 122o F) AC Power Humidity 95% RH max., non-condensing AC Power Maximum Altitude 15,240 meters (50,000 feet) Battery Temperature 0o C to 40o C (32o F to 104o F) Battery Humidity 95% RH max., non-condensing Battery Maximum Altitude 15,240 meters (50,000 feet) Storage Temperature -25o C to 60o C (-13o F to 140o F) Storage Humidity 95% RH max., non-condensing Storage Maximum Altitude 15,240 meters (50,000 feet) OTDR Specifications Module 4415 4425 4436 Emitter Type 1 Laser Diode Laser Diode Laser Diode Center Wavelength 1310 nm ±20 nm 1550 nm ±20 nm 1310 nm ±20 nm 1550 nm ±20 nm 1310 nm ±20 nm 1550 nm ±20 nm Fiber Type Single-mode Single-mode Single-mode Spectral Width (RMS) 1310 nm: <10 nm 1550 nm: <10 nm 1310 nm: <10 nm 1550 nm: <10 nm 1310 nm: <10 nm 1550 nm: <10 nm Dynamic Range 2 1310 nm: 30 dB 1550 nm: 28 dB 1310 nm: 36 dB 1550 nm: 34 dB 1310 nm: 40 dB 1550 nm: 40 dB Initial Reflective Deadzone 3 1310 nm: 3.0meters 1550 nm: 3.0 meters 1310 nm: 3.0 meters 1550 nm: 3.0 meters 1310 nm: 3.5 meters 1550 nm: 3.5 meters Initial Non-Reflective Deadzone 4 1310 nm: 10 meters 1550 nm: 12 meters 1310 nm: 10 meters 1550 nm: 12 meters 1310 nm: 6.0 meters 1550 nm: 6.0 meters Linearity .04 dB/dB .04 dB/dB .04 dB/dB Pulsewidth 10 ns to 20 μs 10 ns to 20 μs 10 ns to 20 μs Distance Resolution 0.0001 km; 0.1 meters; 0.001 kft, 1 ft, 0.0001 mi 0.0001 km; 0.1 meters; 0.001 kft, 1 ft, 0.0001 mi 0.0001 km; 0.1 meters; 0.001 kft, 1 ft, 0.0001 mi Loss Resolution 0.001 dB 0.001 dB 0.001 dB Distance Sampling (range dependent) 0.25, 0.5, 1,5 2, 4, 8, 16 meters 0.25, 0.5, 1,2, 4, 8, 16 meters 0.25, 0.5, 1, 2, 4, 8, 16 meters Distance Range Setting 2/4/8/16/32/64/128/256 km 2/4/8/16/32/64/128/256 km 2/4/8/16/32/64/128/256 km Distance Accuracy 0.0025% of distance measurement + distance resolution + index uncertainty Loss Modes ORL, 2-point, 2-point LSA, dB/KM, dB/KM LSA, splice, dual splice loss, reflectance Trace Compare Modes 4 Trace Overlay, Delta Trace Compare, Align, Stack Data Acquisition Real Time, Fast Scan, Medium Scan, Slow Scan, Timed Average (user selectable) Vertical Scale Settings 0.125/0.25/0.5/1/2/4/8 dB(module dependent) Horizontal Scale Settings 0.001 km/div. to 0.448 km/div. @ 2 km; 0.001 km/div. to 57.304 km/div. @ 256 km (IOR = 1.5) Language Dial-a-language Capability (English, Chinese, Spanish, Portuguese, French, Russian, German, Italian, Swedish, Korean, Hungarian) Notes: 1 Meets CDRH Class 1 Requirements (Eye Safe) 21 CFR 2 SNR=1 with up to 256k averages (Typical, subtract approximately 1.7 dB of range for 98% peak noise. Bellcore TR-TSY-000196 Issue 2) 3 Using Bellcore TR-TSY-000196 Issue (typical) 4 Deadzones measured on -45 dB reflections (typical) 5 Stored Data Points 16,000

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top