Multi-Parameter Patient Monitor GMT-105
Specification:
1. Displayer: 10.4" color TFT LCD screen with maximum 7-waveform display.
Adjusting of lightness continuously make patient more comfortable in midnight
2. Battery: Rechargeable high-energy built-in battery
3. Advanced streamline outline design, portable, compact, lightweight
4. Operating menu with multi-language interface selection: English, Spanish,
Portuguese, Chinese, French, etc.
5. Easy operation with user friendly menu structure design and rotary dial
6. Against electrosurgical interference and defibrillation and no need to disconnect
the monitor from the patient in process of defibrillating.
7. WAN communication function to network with central monitoring system and
make long-distance monitoring, diagnosis, maintenance and software upgrade
possible
8. Optional built-in wireless networking function
9. Support external printer to record graph and trend
10. Intelligent audio and visual comprehensive alarm
11. In-hospital applications include emergency pre-and post-operative care, ambulatory
surgery, intermediate care/step down units, labor and delivery, and hospital-based
special procedure areas
12. Suitable for use in physicians' offices, clinics, outpatient surgical centers, extended
care facilities and other patient care areas, which of require affordable monitoring
Standard configuration: ECG, HR, PR, SpO2, ST analysis, RESP*2 (RA-LL
impedance and nasal cavity), NIBP (with venous punch), TEMP*2(surface and rectal
type), Drug dose calculation.
Optional configuration: Wireless connection, Recorder and ETCO2, 2-IBP
Technical Parameter
. Non-invasive blood pressure
Measurement type: adult, pediatric, neonate
Measurement Systolic 4.0 - 37.0 kPa
range: Diastolic 1.3 - 33.0 kPa
Mean 2.6 - 35.0 kPa
Accuracy : + - 0.4 kPa or 5 %
Resolution: 0.1 kPa
Protection: over pressure
. ECG
Input: 5 wires ECG cable
Lead section: I, II, III / aVR, aVL, aVF/ V
Gain ( mm/mV ) : 1/4, 1/2, 1, 2, 4
Frequency response: Diagnosis 0.05 - 100Hz
Monitor 0.5 - 40 Hz
Surgery 1.0 - 25 Hz
Sweep speed (mm/sec): 12.5, 25, 50
Heart rate range: 30-254 BPM
Heart rate accuracy: + - 1 %
ST segment deviation analysis: -0.8-+0.8mV
ST accuracy: + - 0.02mv
Invasive blood pressure
Measurement range: 0~40kPa (0~300mmHg)
Channel: 2 channel
Transducer sensitivity: 5MV/V/mmHg
Unit display: kPa or mmHg selectable
. Power requirements
Input: 98 - 260 V AC, 50/60Hz
Consumption: < = 80VA
. Safety standard: IEC 60601-1
Quality System: ISO13485: 2003
. Temperature
Measurement range: 25 - 45 centigrade
Accuracy: + - 0.1 centigrade
Resolution: 0.1 centigrade
response time: < = 3 min.
. Respiration Rate
Measurement range: 0 - 120 BPM ( adult )
Accuracy: + - 1 BPM or 5 %
Resolution: 1 BPM
. CO2
Measurement range: 0 %-10.0 %
(ins CO2 and et CO2)
Accuracy: + - 2 mm Hg (< 5 % Measurement value)
10%( >5% Measurement value )
. Pulse oximetry
SPO2 measurement range: 0 - 100 %
Resolution: 1 %
pulse measurement range: 30- 254BPM
Accuracy: + - 2 %
Resolution: 1 BPM
. Environment
Operation Storage
Temperature 0.5 - 40 centigrade -20 - 50 centigrade
Relative humidity < = 80% < = 90%