Pharmaceutical stability test chambers

본문 바로가기


Home > Product > Pharmaceutical stability test chambers
Product
Pharmaceutical stability test chambers
Posting date : Feb 17, 2022
Membership
Free Member Scince Dec 23, 2021
FOB Price
60000
Min. Order Quantity
1
Supply Abillity
7/1 week
Port
shanghai
Payment Terms
cfr
Package
1
Keyword :
Category
Contact
joyce
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
XCH
Model Number
320SD~620SD/CSD
HS-CODE
8401-20
Package & Delivery Lead Time
Package
1
Detailed Description

Pharmaceutical stability test chambers

XCH CSD Series Biomedical stability pharmaceutical chambers, Two case independent control,CSD series, A Chamber has three functions: temperature, humidity and illumination. near ultraviolet lamp tube can be optional,Meet the requirements of the stability test guidelines of the 2020 edition of pharmacopoeia; B Chamber can only control and record temperature and humidity.


Key Features:

• Temperature Control: Temperature Fluctuation ≤ ±0.5℃,Temperature Deviation ≤ ±1.0℃


• Humidity Control: Humidity Fluctuation ≤ ±3%RH,Humidity Deviation ≤ ±3%RH


• Structure Design: Adopt the latest airduct system design achieves good uniform of temperature and humidity form different parts inside the chamber.


• Insulation material: Integral polyurethane foam technology, with good heat preservation and moisture retention performance.


• Chamber Material: The liner is made of mirror stainless steel 304, no pollution source, easy to clean


• Refrigerating System: The imported fully enclosed industrial compressor, long-life, low noise


• Humidity System: Original imported capacitive humidity sensor, direct detection of humidity,maintenance-free


• Control System: Two sets color touch screen temperature and humidity controller,High control accuracy,With three levels permission,audit trail


• Safety device: compressor overheat and overpressure overload protection, Fan overheat protection、water shortage protection.


• Dual Protection: Equipped with double insurance dry fire protection system, equipped with independent overtemperature protection system, can automatically cut off the power supply


• Live Alarm: Temperature and humidity upper limit deviation alarm, independent overtemperature alarm.


• Illumination System: Equipped with illumination sensor,direct illumination display, equipped with illumination storage and printing system


•  CSD series: A with function of illumination, Illumination Range: 100 ~ 8000Lux,Near Ultraviolet Range: 0.84 ~ 5w / m2 ,Illuminance deviation: 4500±500Lux


• Data Record: Equipped with data collection system conform to GMP requirements,Two sets Needle micro printer and USB output port as standard


• Meet a criterion: Meet ICHQ1A(R2)、Q1B、Chinese Pharmacopoeia 2020 edition


• Installed Power: AC220V±10% 50HZ


• Environment temperature: +5~35℃


• SMS alarm: Optional 


Stability chamber specification:

MODELTEMP CONTROL RANGE()HUMIDITY CONTROL RANGE
CAPACITY(L)INTER DIMEN
W×D×H(mm)
EXTER DIMEN
W×D×H(mm)
POWER(KW)Shelf (Standard) Shelf (Standard) 
XCH-320SD
10 ~ 65
20 ~ 95%
150680×500×460
 840×840×1880
2.52Up
10 ~ 65
20 ~ 95%
150680×500×460
2.5
2Down
XCH-520SD
10 ~ 65
20 ~ 95%
250600×500×830
1560×870×1650
3.0
3Up
10 ~ 65
20 ~ 95%
250600×500×830
3.0
3Down
XCH-620SD
10 ~ 65
20 ~ 95%
300600×500×1000
1560×870×1820
3.2
3Left
10 ~ 65
20 ~ 95%
300600×500×1000
1560×870×1820
3Right
Double chamber, independent control


MODELTEMP CONTROL RANGE()HUMIDITY CONTROL RANGE
CAPACITY(L)INTER DIMEN
W×D×H(mm)
EXTER DIMEN
W×D×H(mm)
POWERShelf (Standard) Shelf (Standard) 
XCH-320CSD
15 ~ 65
20 ~ 95%
150680×500×460
 840×840×1880
2.52Up
150
680×500×4602.5
2Down
XCH-520CSD
15 ~ 65
20 ~ 95%
250600×500×830
1560×870×1650
3.0
3Up
250600×500×830
1560×870×1650
3
Down
XCH-620CSD
15 ~ 65
20 ~ 95%
300600×500×10001560×870×18203.23Left
600×500×1000
1560×870×1820
3
Right

Double chamber, independent control

Remark: 

CSD series A equipped with temperature, humidity, visible light and NUV light four functions,Illumination measurement standard with visible and near ultraviolet sensors.Visible and near ultraviolet values are automatically printed and stored;Visible Range: 100 ~ 8000Lux,4500±500Lux,The total illumination of the light test shall not be less than 1.2×106 Lux·hr Near ultraviolet range: 0.84 ~ 5w/m2,Near ultraviolet energy shall not be less than 200w·hr/m2


Application: 

XCH-SD series Medical Stability Testing Chamber Dual Chamber provide long-term stable temperature, humidity and light environment to detect the expiration date of drugs, used for long-term test, accelerated test, high humidity test, strong light irradiation test and drug stability test.


Advantages:

Sensitive, small system error
Two boxes of independent control
No pollution source and is easy to clean
Low cost 


ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us