Portable diesel generator use moving-iron moving-coil analog panel meter

본문 바로가기


Home > Product > Portable diesel generator use moving-iron moving-coil analog panel meter
Product
Portable diesel generator use moving-iron moving-coil analog panel met...
Posting date : Mar 07, 2019
Membership
Free Member Scince Mar 07, 2019
FOB Price
3usd/unit FOBNingbo/Shanghai
Min. Order Quantity
1unit
Supply Abillity
5000units/month
Port
Ningbo/Shanghai
Payment Terms
T/T or Western Union
Package
As per order
Keyword :
Category
Contact
ellen yuan
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
OUHAN
Model Number
SJ-85L17
HS-CODE
9030-39
Package & Delivery Lead Time
Package
As per order
Delivery Lead Time
As per order
Detailed Description
Portable diesel generator use moving-iron moving-coil analog panel meter
This series of instruments directly simulates the display of electrical measurement indications, measure DC current, voltage, AC current, voltage, frequency, power factor, phase sequence, power, synchronization indication and other non-electricity measurements. It is widely used in various railways, DC transmission and distribution systems, power control panels and other electrical equipment for maritime ships, rail transit, chemical explosion-proof, low-voltage complete sets of equipment, construction equipment, generator sets, machinery and equipment industries. Acting on electrical measurement and non-electrical measurement, it is a general-purpose medium and high-grade instrument suitable for general requirements of environmental conditions. Explosion-proof chemical use analyzer testing needle pointer analog panel rack-mount meter
The analog panel meter is in accordance with GB/T7676-1998, the digital display instrument is produced according to GB/T22264-2008 standard, and its safety performance is produced according to GB4793 and IEC61010 standards. The scale and pointer design of the dial conforms to the German DIN43790 and DIN43802 standards. The shape and opening size of the meter are produced in accordance with GB/T1242 and IEC61554 standards.
The CT series base is made of flame retardant TBT plastic with a Vicat temperature of 130 °C. The outer casing is made of flame-retardant ABS plastic with a Vicat temperature of 85 °C.Explosion-proof chemical use analyzer testing needle pointer analog panel rack-mount meter
The reference temperature is 23 °C ± 2 °C, 13 °C ~ 23 °C and 23 °C ~ 33 °C temperature range, the temperature change allowable change is not greater than ± 100% of the grade index.
V.Installation location and installation method: multifunction power meter with RS485
Unless otherwise specified, the meter is usually installed in a vertical position. Other installation locations such as: horizontal installation, tilt installation can be made according to customer requirements. The accuracy level of the response is only valid for the specified installation location. The meter is divided into a right angle of 90 ° and a wide angle of 250 °, two angles of indication.Explosion-proof chemical use analyzer testing needle pointer analog panel rack-mount meter
Anti-vibration: in accordance with IEC60068-2-6 standard; sweep frequency range: 10-55-10Hz; displacement amplitude: ±0.15mm, ±0.3mm. Sweep cycle number: 5 times; sweep rate: 10ct/min; maximum acceleration: 147m/s2 (15g), 490m/s2 (50g). Acceleration effective value: 6.06g; Vibration time: 15min. Anti-mechanical impact, in line with IEC60068-2-27 standard.
VII.Accuracy level:
CT series pointer meter: AC and DC voltmeter and ammeter are 1.5 or 2.5, the power meter is 2.5, the frequency meter is 2.5, and the power factor meter is 2.5.
The overload multiplier is conventionally 1x and 2x overload multiples, which can be customized to 1x, 2x, 3x, etc. by the user. Its role is to indicate the approximate value of the instantaneous overload current, such as the starting current when the motor starts.
The DC current meter has a shunt voltage drop specification of 150mV, 100mV, 75mV, 60mV and 50mV, which can be customized by users. The wire resistance of the meter and the shunt is required to be within 15~25mΩ to ensure the accuracy of the meter.Explosion-proof chemical use analyzer testing needle pointer analog panel rack-mount meter
X.Surface dial:
Surface dial: Made of aluminum alloy, white paint, black ink or laser print. The dial can be customized according to the customer's sample (multiple color overprinting can be customized). The luminous table dial uses a PC board.
Except for the mechanical zero reading instrument, all other instruments have a front zero adjuster for adjusting the mechanical zero position of the instrument.
XII.The main technical parameters: LED three phase digital voltmeter ammeter combination
Name Code Accuracy Commonly used specifications Remarks
AC ammeter A 2.5 0.5-50A Direct connection
AC ammeter A 2.5 10/5A-800/5A Passing secondary current through current transformer
AC ammeter KA 2.5 1KA-10KA Passing secondary current through current transformer
AC voltmeter V 2.5 10V-600V Direct connection
AC voltmeter KV 2.5 1KV-35KV Passed the voltage transformer, the secondary voltage is 100V
DC ammeter uA mA 2.5 50uA-500uA1mA-500mA Direct connection
DC ammeter A 2.5 1A-15A Direct connection
DC ammeter A 2.5 15A-750A Connect with external shunt 75mV,60mV,50mV
DC ammeter KA 2.5 1KA-3KA Connect with external shunt 75mV,60mV,50mV
DC voltmeter V 2.5 3V-600V Direct connection
DC voltmeter KV 2.5 1KV-3KV External fixed resistance is attached

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top