Valve Nominal Diameter DN
|
100-600mm(straight-through Flange connection valves)
|
Maximium Test Pressure PN
|
31.5Mpa(4500LB) Max
|
Nominal Voltage
|
Exchange 380V
|
Rated Power
|
8.5KW
|
Line Voltage
|
Exchange 220V/24V
|
Hydraulic oil
|
N46 hydraulic Oil(provide by user
The oil temperature is Max 60 degrees centigrade ,
Min 5 degrees centigrade
|
Oil circuit system Pressure
|
28Mpa max
|
Test Medium
|
Water(Allows to add rust inhibitor) kerosene or other liquid
it’s viscosity not higher than water
|
Test temperature(Envioment Temp)
|
5 degree centigrade to 40 degree centigrade
|
Transverse clamping Length scope
|
950mm
|
Radial distance
|
100-1350mm
|
Max Clamping Force
|
220(T)
|
Weight
|
4.5tons
|
Size
|
3900×1410×1450(mm)
|
Valve Nominal Diameter DN(mm)
|
200max
|
250
|
300
|
400
|
500
|
600
|
Max Test PressurePN(MPa)
|
31.5
|
28
|
20
|
11
|
7.2
|
5
|
SYTW 600/5-32Valve Test Bench Pressure Comparision Table
|
|||||||||
Norminal Pressure(MPa)
|
2.5
|
4.0
|
6.4
|
10.0
|
16.0
|
20.0
|
25.0
|
32.0
|
|
Test Pressure(MPa)
|
3.75
|
6.0
|
9.6
|
15.0
|
24.0
|
30.0
|
37.5
|
48.0
|
|
Norminal Diameter(DN)
|
Sealing Pressure(MPa)
|
||||||||
in
|
mm
|
||||||||
8
|
200
|
2.2
|
3.5
|
5.6
|
8.8
|
14
|
17.6
|
|
|
10
|
250
|
3.5
|
8.8
|
13.7
|
22.0
|
27.5
|
|
|
|
12
|
300
|
5.0
|
8.0
|
12.7
|
19.8
|
|
|
|
|
14
|
350
|
6.8
|
10.8
|
17.2
|
27.0
|
|
|
|
|
16
|
400
|
8.8
|
14.0
|
22.5
|
|
|
|
|
|
18
|
450
|
11.2
|
17.8
|
28.0
|
|
|
|
|
|
20
|
500
|
13.8
|
22.0
|
|
|
|
|
|
|
22
|
550
|
16.6
|
26.6
|
|
|
|
|
|
|
24
|
600
|
19.8
|
|
|
|
|
|
|
|