500 KV XLPE Insulated Power Cable

본문 바로가기


Home > Product > 500 KV XLPE Insulated Power Cable
Product
500 KV XLPE Insulated Power Cable
Posting date : Oct 17, 2019
Membership
Free Member Scince Oct 10, 2018
FOB Price
-
Min. Order Quantity
100M
Supply Abillity
10000.00KM
Port
Tianjin/Qingdao/Shanghai
Payment Terms
T/T, L/C
Package
wooden drum, steel drum, soft pack
Keyword :
Category
Contact
YANG SONG
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
Huiyou
HS-CODE
-
Package & Delivery Lead Time
Package
wooden drum, steel drum, soft pack
Delivery Lead Time
depending on quantity
Detailed Description
Standard
We produced according to National Standard of GB/T 22078.2-2008 of the People’s Republic of China.
 Range of application
It is suitable for single-core cable’s installation and operation under normal conditions of rated voltage 290/500 KV, but it is not suitable for cable in special use, such as submarine cable.
Characteristics of XLPE cable
Rated voltage of cable is U0=290 KV、U=500 KV、Um=550 KV.
The allowable maximum temperature of cable conductor is 90℃ when it runs in normal, and 250℃ when it short circuited (Longest time is 5 s).
The allowable minimum bending radius is 20 times of cable outside diameter when installed. After installation  , the minimum bending radius is recommended for 15 times of cable outside diameter.
 Service environment( Place )
Lead sheath cable, is suitable for environment with more serious corrosion but no much nitric acid, acetic acid and organic matter ( Such as mud, coal and strong alkaline corrosion matter with technical force, stress and vibration etc.)
Aluminium sheath cable, is suitable for environment with minor corrosion and required to bear a certain mechanical force ( For example, connected with transformer directly and laying at bridge opening or in shaft etc.)
Metal plastic compound sheath cable is suitable for general damp and warm place , no corrosion or light corrosion and no direct contact with water and bear not so much technical force , pulling force , stress and vibration.
PVC outer sheath cable is mainly used in cable line with general fire-proof requirement and insulation requirement for outer sheath.
PE outer sheath cable is mainly suitable for directly buried laying cable line with higher requirement on outer sheath insulation, low temperature environment under 20℃, or soaked place by chemical liquid and low toxicity requirement when cable burns, when PE outer sheath is used in tunnel or shaft , fire-control and flame-retardant measures should be adopted if necessary.
Model and Name of product
Model
 Name of cable
Copper core
YJLW02
XLPE insulated corrugated aluminium sheath or welding  aluminium sheath PVC sheath power cable
YJLW03
XLPE insulated corrugated aluminium sheath or welding aluminium sheath PE sheath power cable
YJLW02-Z
XLPE insulated corrugated aluminium sheath or welding aluminium sheath longitudinally water blocking PVC sheath power cable
YJLW03-Z
XLPE insulated corrugated  aluminium sheath or welding aluminium sheath longitudinally water blocking PE sheath power cable
YJQ02
XLPE insulated lead sheath PVC sheath power cable
YJQ03
XLPE insulated lead sheath PVC sheath power cable
YJQ02-Z
XLPE insulated lead sheath PVC sheath longitudinally water blocking power cable
YJQ03-Z
XLPE lead insulated lead sheath PV sheath longitudinally water blocking power cable
Conductor structure , specifications , insulation thickness
Specifications Conductorcross-section (mm2)
structure
Minimum number of single wire in conductor
Maximum of conductordirect-current resistance(Ω/km)
Insulation nominal thickness
800
Round conductor/Segmental conductor
53
0.0221
34
1000
Segmental conductor
170
0.0176
33
1200
Segmental conductor
170
0.0151
33
1400
Segmental conductor
170
0.0129
32
1600
Segmental conductor
170
0.0113
32
1800
Segmental conductor
265
0.0101
31
2000
Segmental conductor
265
0.0090
31
2200
Segmental conductor
265
0.0083
31
2500
Segmental conductor
265
0.0073
31
 
Representation method of product
For example
A. Single-core copper conductor with rated voltage of 290/500 KV, nominal sectional area of 1200 mm2, so XLPE insulated corrugated aluminium sheath PVC sheath power cable will be represented as : YJLW02-290/500 KV - 1×1200 GB/T 22078.2-2008.
B. Single-core copper conductor with rated voltage of 290/500 KV , nominal sectional area of 2500 mm2, so XLPE insulated corrugated lead sheath PVC sheath longitudinally water blocking power cable  will be represented as : YJQ03-Z-290/500 KV- 1×2500 GB/T22078.2-2008.

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.