I. Introduction
SS-UV-300 flue gas analyzer (low emission monitoring) based on years of experience in research and development of flue gas analyzer, combined with the field practice of nearly ten thousand successful application cases. A number of techniques of the flue gas analyzer (standard form) are upgraded (many times return room to increase gas absorption optical path, and higher accuracy of spectrometer, convection heat transfer core module temperature control, etc.).
The analyzer is based on DOAS and chemometric algorithms (PLS), able to measure concentration of gases including SO2, NO2, NO, O2, NH3, Cl2, O3, H2S, CH3I, etc. It has features of high measure accuracy, outstanding reliability, fast response time and wide applicable scope. All indexes reach or exceed those of domestic & foreign similar products, and fully qualify measurement technology index of low emission monitoring occasions.
II. Application fieldsIt mainly used for industrial boilers, industrial furnaces emissions monitoring in power plant, iron & steel factory, cement plant and son.
 
III. Specifications
 
Model
Standard
Low Emission
Ultra-low Emission
Range
0-300-3000ppm
0-100-300ppm
0-20-100ppm
Linearity
≤±1.5%F.S.
Repeatability
≤±0.5%F.S.
Zero Drift
≤±2%F.S/7d
Span Drift
≤±2%F.S/7d
Response time(T90)
≤10S
≤30S
≤30S
Working Temp
-10℃-+40℃
Preheating time
No preheating
Approx.10 min
Sample Gas Interface
Ø6
 
 
Sample Gas Flow
(0.5-2)L/min,Fluctuation <25%
Sample Gas Pressure
The current encironmental pressure ±0.1 Bar
Sample Temperature
0℃-+50℃
Sample Gas Humidity
No condenstation (under sample temperature)
4-20mA inpt interface
3,configurable,100Ω load
4-20mA Output Interface
5,output can be configured ,maximum load capacity <800Ω
Switch Input Interface
6, configured
Relay Output Interface
14, output ca be configured,DC30V2A
Communication Interface
1*RS232,1*RS485(support the Modbus protocol)
Installation
Installed in 19inch cabinet
Supply
220VAC±10%
Power Consumption
About 100W
About 200W
 
Dimension
132(H)*483(W)*378(D)mm
177(H)*483(W)*412(D)mm
177(H)*483(W)*434(D)mm
Weight
About 10kgs
About 12kgs
 
 
 
IV. Product feature
1. High measurement accuracy
2. The minimum detection limit of SO2 , NO2, NO can be 1mg/m3 (15m optical path)
3. Ultraviolet has no moisture absorption, undisturbed by moisture and dust.
4. No cross interference between the gas being measured (see table 1)
5. NO and NO2 can be measured at the same time, dispense with converter
6. High reliability
7. White cell + DOAS + PLS technology, small amount of zero drift and span drift
8. Modular design
9. No optical moving parts and no vibration influence
10. Strong gas cell, low cost
11. Spectrum automatic adjustment technology, long free maintenance cycle
12. Light source adopts the pulse source, the service life is 10 years
 

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top