High altitude low pressure simulation test chamber

본문 바로가기


Home > Product > High altitude low pressure simulation test chamber
Product
High altitude low pressure simulation test chamber
Posting date : Aug 22, 2018
Membership
Free Member Scince Jul 13, 2018
FOB Price
negotiate
Min. Order Quantity
1 set
Supply Abillity
50000 sets per year
Port
Shenzhen,Hongkong,Guangzhou
Payment Terms
1,100% T/T; 2, Alibaba Trade Assurance;3,30% TT+70% L/C or 100% L/C at sight.
Package
Export Wooden case
Keyword :
Category
Contact
Ben Zhao
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
GRANDE
HS-CODE
-
Package & Delivery Lead Time
Package
Export Wooden case
Delivery Lead Time
1 working day
Detailed Description
Temperature testing at altitudes up to 100,000 feet.
Grande can provide custom-built chambers for simultaneous testing of temperature and low-pressure altitude conditions. Two common applications are:
Testing of avionics or other aerospace equipment to simulate actual conditions it might experience.
Simulation of high-altitude conditions like might be found in mountainous regions.
NOTE: Altitude test chambers are custom systems, and differing requirements may significantly change the cost and utility requirements. Please let Grande know as much detail as possible about your anticipated testing specification/method, and we can provide you with a tailored system for your requirements.
Features
Temperature range from -70 to 200°C
Altitude range from ground to 100,000 feet
Optional humidity control when altitude system is off
Chamber interior size specified by customer
Automatic altitude control, integrated with temperature controller—No manual setting of altitude level!
Vacuum pump sized for climb/dive rate required by application
Viewing window and cable ports available
Corresponding Standard of the Temperature and Humidity Test Chamber:
1.GB10590-89  Low-temperature and low atmospheric pressure testing condition
2.GB10591-89 High-temperature and low atmospheric pressure testing condition
3. GB11159-89 low atmospheric pressure technical condition
4. GB/T2423.25-1992 Low-temperature and low atmospheric pressure test chamber
5. GB/T2423.26-1992 High-temperature and low atmospheric pressure test chamber
6.GJB150.2-86 High-temperature and low atmospheric pressure(Altitude) test
7,IEC60068-2-1.1990 Testing methods of Low-temperature test chambers
8,IEC60068-2-2.1974 Testing methods of High-temperature test chambers
9,IEC-540
10,ASTM D2436
11,JIS K7212
12,DIN 50011
13,BS2648
14,Mil-Std 202G (conditions 105C, A/B/C/F)
15,Mil-Std 810G (condition 500.5)
16,IEC 60068-2-39
17,IEC 60068-2-40
18,RTCA/DO-160F
19,JIS W 0812
Technical parameters:
Model No  
GATC-150
GATC-225
GATC-408
GATC-800
GATC-1000
Working room(L)
150
225
408
800
1000
Inner chamber size(mm)W*H*D 
500*600*500
500*750*600
600*850*800
1000*1000*800
1000*1000*1000
Exterior chamber size(mm)W*H*D
1000*1600*1400
1000*1750*1500
1100*1850*1700
1500*2000*1700
1850*1600*2250
Packaging volume(CBM)
3
3.5
4.5
5.5
6
G.W.(KGs)
320
350
400
600
700
Testing temperature range
-80°C,-73°C,-60°C, -40°C, -20°C, 0°C~+150°C, +200°C (300°C)
Performance
Temperature range
-65℃~150℃
Temp.fluctuation
±0.5℃(Room pressure)
Temp.accuracy
±2.0℃(Room pressure)
Heating up time
≤60min(+20℃~+150℃、RP、No-Load)
Cooling down time
≤45min(RP)
≤60min(RP)
≤90min(RP)
Pressure range
 RP~0.5kPa
Pressure control tolerance
±0.1kPa(≤2kPa),±5%(2kPa~40kPa),±2kPa(≥40kPa)
Depressurization time
≤20min
≤25min
≤30min
≤45min
≤50min
Working environment
Temp:+5℃~+35℃;Humidity:≤90%RH;Airpressure:86-106kPa
Material
Exterior chamber materia
Stainless steel plate+ powder coated
Inner chamber materia
SUS#304 stainless steel plate
Insulation Material
PU Fiberglass wool
System
Air circulation system
Cooling fan
Heating System
SUS#304 stainless steel high-speed heater
Humidification system
Imported compressor,Tecumseh compressor(or Bizer Compressor),finned type evaporator,air(Water)-cooling condenser
Dehumidification system
ADP critical dew point cooling/dehumidifying method
Controlling system
TEMI880,990
Power kw
8
10
12
15
20
Water supply
Water temperature:≤30℃;water pressure:0.2~0.4MPa;flow rate:≥10T/h 
Other components
Specimen holders 2pcs,electrical wire 1pc(3M),pressure testing port.
Safety protection device
Over-heat protection circuit breaker,Compressor overload protection,Control system overload protection,Humidifying system overload protection,Overload indicator lamp.
Power supply
AC 3Ψ380V 60/50Hz
Customized service
Welcome to Non-standard,Specail requirements,OEM/ODM orders.
 
Optional accessories
1,Low Humidity and Dehumidifying sytstem.
2,Inner glass door with manual operating ports.
3,Temp./Humi.Recorder.
4,Pure water treatment device
5,RS-485 interface can be linked to Personal computer(PC) and achieve multi-level control & recording software management.
6,Liquid nitrogen(LN2)/Liquid Carbon Dioxide(LCO2) fast cooling-down system.
 

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2025 ECROBOT.COM. All rights reserved.