120A 500V Portable Meter Test Equipment AC Voltage And Current Source Class 0.05

본문 바로가기


Home > Product > 120A 500V Portable Meter Test Equipment AC Voltage And Current Source Class 0.05
Product
120A 500V Portable Meter Test Equipment AC Voltage And Current Source ...
Posting date : Feb 07, 2018
Membership
Free Member Scince Jan 25, 2018
FOB Price
20000-30000USD/SET
Port
BEIJING CHINA
Payment Terms
L/C, D/A, D
Package
Standard Export Wooden Box
Keyword :
Category
Contact
GFUVE
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
GFUVE
Model Number
GF303D
HS-CODE
82-
Package & Delivery Lead Time
Package
Standard Export Wooden Box
Delivery Lead Time
2-3weeks
Detailed Description
120A 500V Portable Three Phase AC Voltage And Current Source Class 0.05 The GF303Dis a powerful and portable three phase current and voltage source. All test values are generated absolutely synthetically with a high degree of accuracy, low phase shiftand stability. The source is available in 12 A, 24A or 120 A. The GF303Dthree phase portable power source is a lightweight and portable three phase current and voltage source based on newest technology and serves for solving this problem by simulating the required load conditions. Operation is performed by integrated 7 touch screen or via keyboards. APPLICATION It is suitable for power department, measuring department, quality control department, research units, and institutions of higher learning, and electric energy meter, power distribution terminals, power supply management, load control, power quality, reactive power compensation device and the production of enterprise etc. FEATURES # To set up and take the load regulation of voltage, current, phase angle ,frequency and power factor etc; as a large current source, voltage source and power source # To set 2 ~ 31 times of the amplitude and phase harmonics, and it can be added to the base wave in every harmonic output # Voltage, current output a wide range, big power, high stability, waveform distortion degree is small # Strong with load ability, but it can take capacitive, sensibility, resistance of composite type load or load and load regulation is higher than 0.01% # To apply the 32 bit MPU + DSP + CPLD, powerful flexible # To use hardware PID, fast response, the change of load will not cause output volatility # Industrial frequency waves as high as 5000 points a week of the wave kneading, signal output without filter, precise output waveform, the harmonic output precision, harmonic distortion degree is small # Range switching automatically # To use software calibration, simple operation, stable and reliable # Display of vector diagram, adjustable to IEC387 OR DIN410 # Big touch screen, 7-inch TFT color LCD display, English interface, operating simply # To have perfect over-current, over-voltage, heat, a shorts-and-opens, overload protection, failure detection automatically # With RS232 interface, and PC connection # To take place machine software, it can be output through the PC software program PARAMETERS - - - - Electrical parameters Accuracy class | 0.05%, 0.1% | Power supply | Single phase AC 85-265 V, frequency 50/60 Hz | AC Voltage output Range (U1, U2, U3 phase) | 57.7V/100V/220V/380V; range switch automatically(Max 500V) | Adjust fineness | 0.01% RG | Accuracy | 0.05% RG | Stability | <0.01% RG/120s | Distortion degree | <0.3% (not capacitive load) | Output power | 25VA | Full load regulation rate | 0.01% RG | Full load regulation time | Less than 1mS | Long-term stability | 60 PPM/year | AC Current output Range (I1, I2, I3 phase) | 0.2A, 1A, 5A, 20A, 100A; range switch automatically | Adjustment range | (0-120)%RG | Adjust fineness | 0.01% RG | Accuracy | 0.05% RG | Stability | <0.01% RG/120s | Distortion degree | <0.3% (not capacitive load) | Output power | 45VA | Full load regulation rate | 0.01% RG | Full load regulation time | Less than 1mS | Long-term stability | 60 PPM/year | Power output Accuracy | 0.05% RG | Stability | 0.01% RG/120s | Phase angle Adjusting range | 0-359.99 | Resolution | 0.001 | Accuracy | 0.05 | Power factor Adjusting range | -1 ~ 0 ~ +1 | Resolution | 0.0001 | Accuracy | 0.0005 | Frequency Adjusting range | 40-65 Hz | Resolution | 0.001 Hz | Accuracy | 0.005 Hz | Temperature drift | 0.5 PPM/C | Long-term stability | 4 PPM/year | Harmonic accuracy Harmonic phase | 0-359.99 | Harmonic phase accuracy | < 0.01 | Harmonic set accuracy | 0.1% (relative to the base wave ratings) | Mechanical parameters Dimensions (WDH) (mm) | 500x600x175 | Weight (kg) | 27 | Environmental conditions Working temperature | 0C to 40C | Storage condition | -30C to -60C | Relative humidity | 85% | - - - - SELECTION GUIDE - - - - NO. Accuracy Voltage range Current Range Weight 303D1201 | 0.10% | 0-500V | 0-120A | 27KG | 303D12005 | 0.05% | 0-500V | 0-120A | 27KG | 303D1201 | 0.10% | 0-380V | 0-12A | 18KG | 303D1205 | 0.05% | 0-380V | 0-12A | 18KG | 303D2401 | 0.10% | 0-500V | 0-24A | 20KG | 303D2405 | 0.05% | 0-500V | 0-24A | 20KG | - - - - Photo

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top