High Temperature Dual Pipe 4 Row Horizontal Fan Coil Unit ESP 50 pa

본문 바로가기


Home > Product > High Temperature Dual Pipe 4 Row Horizontal Fan Coil Unit ESP 50 pa
Product
High Temperature Dual Pipe 4 Row Horizontal Fan Coil Unit ESP 50 pa
Posting date : Nov 07, 2017
Membership
Free Member Scince Oct 19, 2017
FOB Price
negotiation
Port
China
Payment Terms
L/C, T/T
Package
Carton
Keyword :
Category
Contact
LENG
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
EuroKlimat
Model Number
EKCW-A
HS-CODE
83-
Package & Delivery Lead Time
Package
Carton
Delivery Lead Time
10 working days after received your payment
Detailed Description
Dual pipe 4 rows large temperature horizontal concealed fan coil unit ESP 50 pa Specifications - - - - Model Performance | EKCW 200AA | EKCW 300AA | EKCW 400AA | EKCW 500AA | EKCW 600AA | EKCW 800AA | EKCW 1000AA | EKCW 1200AA | EKCW 1400AA | Rated air flow (m3/h; under static pressure of 12 Pa, 30 Pa, and 50 Pa) | H | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 | M | 279 | 418 | 558 | 697 | 836 | 1115 | 1394 | 1673 | 1952 | L | 170 | 255 | 340 | 425 | 510 | 680 | 850 | 1020 | 1190 | Rated cooling capacity (W) | Total heating/cooling capacity | H | 2125 | 3385 | 4390 | 4902 | 6207 | 8096 | 10165 | 11066 | 13744 | Sensible heating/cooling capacity | H | 1233 | 2059 | 2848 | 3353 | 4179 | 5572 | 7125 | 7961 | 9770 | Rated heating capacity (W) | H | 3576 | 5427 | 6915 | 8335 | 12238 | 13216 | 16587 | 18339 | 22160 | Rated input power (W) | Static pressure of 12 Pa | H | 32 | 46 | 56 | 73 | 93 | 133 | 164 | 188 | 229 | Static pressure of 30 Pa | H | 41 | 53 | 72 | 86 | 107 | 142 | 183 | 217 | 239 | Static pressure of 50 Pa | H | 46 | 65 | 77 | 90 | 115 | 162 | 187 | 227 | 279 | Working current (A) | Static pressure of 12 Pa | H | 0.15 | 0.21 | 0.26 | 0.33 | 0.42 | 0.61 | 0.74 | 0.85 | 1.04 | Static pressure of 30 Pa | H | 0.20 | 0.24 | 0.33 | 0.39 | 0.48 | 0.65 | 0.83 | 0.99 | 1.09 | Static pressure of 50 Pa | H | 0.21 | 0.29 | 0.35 | 0.41 | 0.52 | 0.74 | 0.85 | 1.03 | 1.27 | Sound dB(A) | Static pressure of 12 Pa | H | 33.5 | 32.5 | 38.5 | 41.5 | 44.5 | 45.0 | 48.0 | 49.0 | 51.0 | Static pressure of 30 Pa | H | 39.5 | 40.0 | 43.0 | 44.0 | 46.0 | 46.0 | 50.5 | 50.5 | 51.5 | Static pressure of 50 Pa | H | 42.0 | 43.0 | 45.0 | 46.0 | 47.5 | 48.5 | 50.5 | 52.5 | 53.0 | Water flow (m3/h) | 0.21 | 0.33 | 0.43 | 0.48 | 0.60 | 0.79 | 0.99 | 1.07 | 1.32 | Water resistance (cooling) (kPa) | 5 | 13 | 22 | 10 | 16 | 16 | 25 | 20 | 29 | Water resistance (heating) (kPa) | 4 | 9 | 18 | 8 | 13 | 13 | 20 | 17 | 24 | Coil | Type | Mechanically expanded quality copper tubes specially designed for air conditioners with shutter-type hyperbolic aluminum fins | Working pressure | 1.6MPa | Test pressure | Airtightness test under pressurized water: 3.3 MPa | Fan | Type | Forward-pitched multi-wing centrifugal fan with double-suction impellers made from zinc-plated steel plates | Qty. | 1 | 2 | 2 | 2 | 2 | 3 | 4 | 4 | 4 | Motor | Type | Single-phase ball-bearing capacitive motor with a high precision and low operation sound | Qty. | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | Power supply | 220V~/50Hz | Protection grade | IP20 | Insulation grade | B | Inlet/outlet water pipe | Pipe diameter | Rc3/4 taper pipe with internal thread | Condensate water pipe | Pipe diameter | Diameter R 3/4 taper pipe with external threads | Net weight (no electric heater) | No return air plenum | kg | 11.8 | 14.3 | 16.8 | 17.9 | 19.1 | 28.4 | 31.4 | 34.3 | 41.3 | With return air plenum | kg | 14.8 | 17.9 | 20.8 | 22.2 | 23.7 | 34.4 | 37.8 | 41.5 | 49.5 | Electric heater (optional) | Power supply | | 220V~/50Hz | 380V/3N~/50Hz | Electric heating capacity | kW | 1.0/2.0 | 1.0/2.0/3.0 | 2.0/3.0/4.0 | 2.0/3.0/4.0 | 2.0/3.0/4.0 | 3.0/4.0/5.0 | 3.0/4.0/5.0 | 4.0/5.0/6.0 | 5.0/6.0/7.0 | Net weight (with electric heater) | No return air plenum | kg | 14.9 | 17.5 | 20.5 | 21.8 | 23.2 | 33.4 | 36.6 | 40.1 | 47.8 | With return air plenum | kg | 17.9 | 21.1 | 24.5 | 26.1 | 27.8 | 39.4 | 43.0 | 47.3 | 56.0 | - - - - Note: Working conditions for cooling: inlet air temperature - dry/wet bulb 27C/19.5C; temperature of inlet/outlet water - 5C/15C. Working conditions for heating: inlet air temperature - dry bulb 21C; inlet water temperature 60C; water flow - equal to that for cooling operation. Rated air flow is measured under standard atmosphere using dry coils (dry bulb 20C). Sound pressure grade and sound level are measured in a semi-silent room as per GB/T 19232-2003. H, M and L represent high, medium and low fan speed respectively. Static pressure refers to outlet static pressure. All performance parameters in the above table are measure with a power supply of 220V~/50Hz. The right/left orientation of connection pipes are exchangeable on site (cooling/heating capacity needs to be multiplied by a correction factor of 0.93 after exchange). 1.Compact Exterior With a compact, graceful and robust design, this super-thin unit can be concealed in a small space inside the ceiling. 2.Low Noise The unit features a forward-pitched low-speed centrifugal fan with wide impellers. The fan has a good dynamic balance and a stable performance, and minimizes the operation sound while ensuring enough air flow and the static pressure of outlet air by using efficient sound-dampening and heat-insulation material. 3.Efficient and Energy Saving To maximize heat transfer and exchange efficiency, the unit features heat exchange coils made of quality copper tubes, efficient hyperbolic aluminum shutter fins, precise mechanic tube expansion and a fan with wide impellers and a high air supply capacity. 4.Easy and Flexible Installation The unit features a symmetric design and can be easily installed. The left and right connection pipes are exchangeable. For units with a return air plenum, the air return mode can be customized. 5.Safe and Leakage-proof The condensate water collector are molded as a whole (no welding line or dots) and entirely coated with fireproof material to prevent leakage. A specially designed pitch on the collector also helps ensure smooth discharge of condensate water. 6.Easy Maintenance The unit features a single-phase capacitive motor with a low operation sound and a long service life thanks to a quality precision ball bear that is hermetic, fully lubricated, rustproof and durable. All wires leading out of the motor are protected against damage using flexible metal tubes.

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top