65.5kW COP 3.38 High Efficiency Air Cooled Modular Chiller / Heat Pump Units

본문 바로가기


Home > Product > 65.5kW COP 3.38 High Efficiency Air Cooled Modular Chiller / Heat Pump Units
Product
65.5kW COP 3.38 High Efficiency Air Cooled Modular Chiller / Heat Pump...
Posting date : Nov 07, 2017
Membership
Free Member Scince Oct 19, 2017
FOB Price
negotiation
Port
China
Payment Terms
L/C, T/T
Package
Carton
Keyword :
Category
Contact
LENG
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
EuroKlimat
Model Number
EKAC 230B(R)
HS-CODE
83-
Package & Delivery Lead Time
Package
Carton
Delivery Lead Time
20 working days after received your payment
Detailed Description
Low-temp high-efficiency model Air-cooled Heat Hump Unit Specifications: EKAC modular air-cooled heat pump units combines more than 40 years of Italian air-cooled heat pump design experience and the application practices of modular units in China, so as to meet customers' requirements on product efficiency, safety, smartness and comfort. This series of units have diversified models and are applicable to various environments, such as villas, hotels, recreation centers, hospitals, dining halls, office buildings, supermarkets, and various industrial processes that requires cooling. Technical data sheet - - - - Model | | EKAC 230B | EKAC 230BR | EKAC 460B | EKAC 460BR | EKAC 690B | EKAC 690BR | Unit combination | Master unit | EKAC 230BM | EKAC 230BRM | EKAC 230BM | EKAC 230BRM | EKAC 230BM | EKAC 230BRM | slave unit | - | -- | EKAC 230BS | EKAC 230BRS | 2EKAC 230BS | 2EKAC 230BRS | Nominal cooling capacity | kW | 65.5 | 65.5 | 131 | 131 | 196.5 | 196.5 | USRT | 18.63 | 18.63 | 37.26 | 37.26 | 55.88 | 55.88 | 104kcal/h | 5.63 | 5.63 | 11.26 | 11.26 | 16.90 | 16.90 | Nominal heating capacity | kW | -- | 69 | -- | 138 | -- | 207 | USRT | -- | 19.62 | -- | 39.2 | -- | 58.9 | 104kcal/h | -- | 5.93 | -- | 11.9 | -- | 17.8 | Total power of nominal cooling capacity | kW | 19.4 | 19.4 | 38.8 | 38.8 | 58.2 | 58.2 | Total power of nominal heating capacity | kW | -- | 19.2 | -- | 38.4 | -- | 57.6 | Power supply | | 380V/3N~/50Hz | Refrigerant | Type | | R22 | Control | | Electronic expansion valve | Compressor | Type | | Fully hermetic volute compressor | Lubricant | | Mineral oil (SUNISO 3GS) | Qty. | Set | 2 | 2 | 4 | 4 | 6 | 6 | Fan | Type | | High-efficiency vacuum braze-welded panel type | Qty. | Set | 2 | 2 | 4 | 4 | 6 | 6 | Water side heat exchanger | Type | | High-efficiency vacuum braze-welded panel type | Water flow for cooling | 3 m /h | 11.3 | 11.3 | 22.6 | 22.6 | 33.9 | 33.9 | Water flow rate in heating mode | 3 m /h | -- | 11.9 | -- | 23.8 | -- | 35.7 | Water resistance | kPa | 45 | 45 | 45 | 45 | 45 | 45 | Recommended diameter for general inlet/outlet water pipe | inch | 2 | 2 | 3 | 3 | 3 | 3 | Power cable specification | Section area of live line | 2 mm | 10 | 10 | 35 | 35 | 70 | 70 | Qty. of live lines | | 3 | Section area of null line | 2 mm | 4 | Qty. of null lines | | 1 | Section area of grounding line | 2 mm | 10 | 10 | 16 | 16 | 35 | 35 | Qty. of grounding lines | | 1 | Dimensions | L x H | mm | 20121840 | Width | mm | 880 | 880 | 2125 | 2125 | 3370 | 3370 | Unit weight | Net weight | kg | 500 | 520 | 1000 | 1040 | 1500 | 1560 | Operating weight | kg | 510 | 530 | 1020 | 1060 | 1530 | 1590 | - - - - - - - - Model | | EKAC 920B | EKAC 920BR | EKAC 1150B | EKAC 1150BR | EKAC 1380B | EKAC 1380BR | Unit combination | Master unit | EKAC 230BM | EKAC 230BRM | EKAC 230BM | EKAC 230BRM | EKAC 230BM | EKAC 230BRM | slave unit | 3EKAC 230BS | 3EKAC 230BRS | 4EKAC 230BS | 4EKAC 230BRS | 5EKAC 230BS | 5EKAC 230BRS | Nominal cooling capacity | kW | 262 | 262 | 327.5 | 327.5 | 393 | 393 | USRT | 74.51 | 74.51 | 93.14 | 93.14 | 111.77 | 111.77 | 104kcal/h | 22.53 | 22.53 | 28.16 | 28.16 | 33.79 | 33.79 | Nominal heating capacity | kW | -- | 276 | -- | 345 | -- | 414 | USRT | -- | 78.5 | -- | 98.1 | -- | 117.7 | 104kcal/h | -- | 23.7 | -- | 29.7 | -- | 35.6 | Total power of nominal cooling capacity | kW | 77.6 | 77.6 | 97.0 | 97.0 | 116.4 | 116.4 | Total power of nominal heating capacity | kW | -- | 76.8 | -- | 96.0 | -- | 115.2 | Power supply | | 380V/3N~/50Hz | Refrigerant | Type | | R22 | Control | | Electronic expansion valve | Compressor | Type | | Fully hermetic volute compressor | Lubricant | | Mineral oil (SUNISO 3GS) | Qty. | Set | 8 | 8 | 10 | 10 | 12 | 12 | Fan | Type | | High-efficiency vacuum braze-welded panel type | Qty. | Set | 8 | 8 | 10 | 10 | 12 | 12 | Water side heat exchanger | Type | | High-efficiency vacuum braze-welded panel type | Water flow for cooling | 3 m /h | 45.2 | 45.2 | 56.5 | 56.5 | 67.8 | 67.8 | Water flow rate in heating mode | 3 m /h | -- | 47.6 | -- | 59.5 | -- | 71.4 | Water resistance | kPa | 45 | 45 | 45 | 45 | 45 | 45 | Recommended diameter for general inlet/outlet water pipe | inch | 4 | 4 | 4 | 4 | 5 | 5 | Power cable specification | Section area of live line | 2 mm | 95 | 95 | 120 | 120 | 150 | 150 | Qty. of live lines | | 3 | Section area of null line | 2 mm | 4 | Qty. of null lines | | 1 | Section area of grounding line | 2 mm | 50 | 50 | 60 | 60 | 75 | 75 | Qty. of grounding lines | | 1 | Dimensions | L x H | mm | 20121840 | Width | mm | 4615 | 4615 | 5860 | 5860 | 7105 | 7105 | Unit weight | Net weight | kg | 2000 | 2080 | 2500 | 2600 | 3000 | 3120 | Operating weight | kg | 2040 | 2120 | 2550 | 2650 | 3060 | 3180 | - - - - Note: Test conditions for nominal cooling capacity: outlet water temperature 7C; water flow: 0.172m3/(hkw); outdoor ambient temperature 35C. Test conditions for nominal heating capacity: outlet water temperature 45C; water flow: 0.172m3/(hkW); outdoor dry/web bulb temperature 7C/6C. Water resistance at the air conditioner side includes water pressure drop of the unit and the attached Y-shaped filter. Main Pipes of combined units need to be customized and installed on site. The diameter of the pipes must meet design requirements. EK does not provide the pipes. Modular units can be formed using the 1 - 16 basic modules of same type or of different types as per practical needs. The above table lists the parameters for common module combinations. For on-site electric wiring, see the name plate or installation menu of the unit. Description: 1. Based on its leading-edge design for air cooled and heat pump units in Europe as well as the wide use of its air-cooled units in China, EK has launched this series of innovative modular air-cooled water chiller (heat pump) units. The full-load COP of this series is higher than that the energy saving product certification standard 2. Each modular unit has two power gears. When multiple modular units are combined, there could be many power gears. Fully-optimized model selection and matching practice ensures that the units can always save as much energy as possible. When operating with a partial load (99% of full operation time), the EER is even 4% higher. 3. With an optional 2-way valve water control feature, the unit can send out signals to turn off corresponding chilled water valves. This enables automatic flow control for pumps in line with the transducer, which helps save more energy. 4. The unit features modular design and starts up in steps to ease the shock on the power grid caused by startup current. 5. The unit has undergone strict and long-duration tests according to the most stringent standards, and can work reliably to providing cooling when the ambient temperature is as high as 48 and heating when the ambient temperature is as low as -10. 6. The system features built-in high/low pressure protection, cooling freezing protection, winter freezing protection, compressor overload protection and water pressure-drop switch etc. to maximize the safety of the unit. 7. The unit uses a 500-step PMV electronic expansion valve for precise PID control, dynamic and real-time adjustment of the cooling system, and higher-precision water temperature control. This helps optimize the performance of each and every part of the system. The unit can work reliably under any load and automatically adapt to changing ambient temperatures, completely eliminating cooling system vibration. 8. The entire unit features vibration isolation design and multiple noise reduction processes. Both noise level and vibration level of the unit take the lead in the industry thanks to its name-brand quite hermetic volute Compressors and two-gear quiet fans. The noise level of the unit is significantly reduced using professional noise reduction practices, such as comparing, choosing and improving fans, motors, structures and pipelines based on noise spectrum analysis results. 9. Innovative smart silencing mode can automatically adjust the fan rev (high/low) according to outdoor temperature and the operation status of the unit. This makes the unit even quieter in operation mode. 10. The unit needs no additional equipment room, and can be mounted on the floor, building roof, etc. Modular design makes each unit small in dimension and suitable for transportation by cargo elevator, thus saving hoist cost during construction. The unit can also be installed step by step to shorten the construction period. 11. Each unit has a separate refrigerant circuit. This reduces the probability of refrigerant leakage which could damage the ozonosphere. 12. The unit uses a micro-computer controller with a large LCD screen to facilitate operation. Each controller can control and dynamically monitor the operation of up to 16 units. This facilitates centralized management.

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top