YH10W5-12 Substation Surge Arrester without Gaps, KEMA
Description:
YongDe Surge Arresters can be applied to a variety of systems including substation equipment, AC-DC converters, railway power system and power distribution units ranging from 0.25kV to 765kV systems. These surge arresters demonstrate excellent protection properties. YongDe surge arresters incorporate YNR elements (YongDe Non-linear Resistor ZnO Elements) with superior non-linear voltage-current characteristics, high quality and reliability. Metal oxide type surge arresters offer such special features inherent in the gap-less structure, such as a quick response to surge voltage, high energy dissipation capability, safe operation, compactness / lightweight and freedom from pollution.
Product characteristic:
1. Small size,Light weight,resistance to impact,no collision damage during
transportation,flexible installation,suitable for use in the switch cabin.
2. Special structure,the overall compression molding,no air gap,good sealing
performance,moisture-proof and explosion-proof
3. Large creepage distance,good hydrophobicity,strong stain resistance,stable
performance and reduce operation maintenance.
4. Unique formula of zinc oxide varistor, small leakage current,slow aging,long
service life.
5. With DC reference voltage,rectangular flow capacity and high current and large
current withstand capacity are higher than standard requirement.
Specifications:
- - - -
Type | YH10W5-12 | | |
Rated voltage---------kV | 12 | 4/10S High current impulse kA | 100 |
MOCV ----------------kV | 10.2 | Lightning impulse withstand kV | 110 |
Nominal Current-------kA | 10 | Power frequency voltage withstand(dry/wet)kV | 28 |
Residual voltage of steep impulse----at 5kA(kV) | 36 | 0.1S TOV--------------kV | 14.4 |
8/20S Residual voltage of lightning impulse current kV(Peak value)-----at 5kA(kV) | 33 | 1S TOV----------------kV | 13.8 |
Residual voltage of switching impulse current kV (peak value)----at 1kA (kV) | 31.5 | 10S TOV---------------kV | 13.2 |
1mA D.C reference voltage (kV) | 17 | 1200S TOV-------------kV | 12 |
Line discharge level | 1 | Creepage distance ----mm | 434 |
2mS long duration impulse current A | 400 | Material employed in series non-linear resistor | Zinc Oxide |
- - - -
Packing details:
1) Size: 430mmX145mmX160mm with 3pieces per carton
2) Packing: Carton with polyfoam insert parts
3) Weight: 4.2kg/carton
4) Loading Port: Ningbo/ Shanghai(Or as customer requirement)
5) Loading Ability: 20'GP 4500sets / 40'GP 9000sets
Working condition:
1) Environment temperature: -40--+40 degree
2) altitude: <1000m
3) 48HZ
4) Power frequency voltage should not be more than continuous running voltag
5) Max wind speed should be less than 35m/s
6) Earthquake intensity should be less than 7 degree
7) If used in contamination area, should be noted in advance.