Touch Screen Thermal Shock Chamber Air To Air 3 Zone For Car Accessory Testing

본문 바로가기


Home > Product > Touch Screen Thermal Shock Chamber Air To Air 3 Zone For Car Accessory Testing
Product
Touch Screen Thermal Shock Chamber Air To Air 3 Zone For Car Accessory...
Posting date : Oct 18, 2017
Membership
Free Member Scince Sep 28, 2017
FOB Price
Up to the quantity
Port
Dongguan, China
Payment Terms
L/C, D/A, D
Package
Packed in carton firstly, and then reinforced with
Keyword :
Category
Contact
David
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
SANWOOD
Model Number
SM-202-3P
HS-CODE
83-
Package & Delivery Lead Time
Package
Packed in carton firstly, and then reinforced with
Delivery Lead Time
45 working days
Detailed Description
Air To Air 3 Zone Thermal Shock Test Chamber For Car Accessary Testing 1. Thermal Shock Chambers : Thermal shock chamber is metal, plastic, rubber, electronics and other industries necessary testing equipment. For the continuous exposure to extremely high temperature, very low temperature environment, instant exposure of the material structure or composite material tolerance, can be detected in the shortest possible time due to thermal expansion and contraction caused by chemical or physical damage. The SANWOODthermal shock chamber meets today's environmental stress screening requirements and is proven in installations around the world. Our hot and cold direct transfer method is an economical way to achieve ESS or thermal shocks for rapid component temperature changes. 2. 3-Zone Thermal Shock Chambers Application: Such chambers heretofore known include one comprising a test area for the test sample, a high-temperature air conditioning unit having gas outlet and intake adapted to communicate with the test area, an outside air supplying unit having air outlet and inlet adapted to communicate with the test area, and a low-temperature air conditioning unit having gas outlet and intake adapted to communicate with the test area. The thermal shock chamber of this type is provided with three dampers, i.e., one for opening or closing the gas outlet and intake of the high-temperature air conditioning unit, another for the air outlet and inlet of the outside air supplying unit, and another for the gas outlet and intake of the low-temperature air conditioning unit. 3. Specification (1) SM-3P-A Series - - - - Model | - - - - SM-3P-ASeries | - - - - | 72A | 100A | 150A | 200A | 252A | 300A | 480A | Inside size(mm) | W | 450 | 500 | 600 | 670 | 700 | 800 | 800 | H | 400 | 450 | 500 | 600 | 600 | 600 | 800 | D | 400 | 450 | 500 | 500 | 600 | 650 | 750 | Outside size(mm) | W | 1490 | 1540 | 1640 | 1720 | 1750 | 1850 | 1850 | H | 1790 | 1840 | 1890 | 2000 | 2000 | 2000 | 2200 | D | 1600 | 1700 | 1830 | 1850 | 1930 | 1980 | 2500 | Test weight | 5 | 10 | 12 | 15 | 18 | 20 | 20 | Low Temp Chamber | -55C-10C, Pre cooling time: 60 min from +20Cto-55C | Test Chamber | -40C+150C | High Temp Chamber | +60C+200C ,Within 20 min, Pre-heating time | Transition time | 15S | Recovery time | High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample | Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample | 5 min | Ambient Temp. | +5C+35C | Power | AC 38010 50Hz ,3 phase 4 wires +Ground Wires | - - - - (2) SM-3P-BSeries - - - - Model | - - - - SM-3P--B Series | - - - - | 72B | 100B | 150B | 200B | 252B | 300B | 480B | Inside size(mm) | W | 450 | 500 | 600 | 670 | 700 | 800 | 800 | H | 400 | 450 | 500 | 600 | 600 | 600 | 800 | D | 400 | 450 | 500 | 500 | 600 | 650 | 750 | Outside size(mm) | W | 1490 | 1540 | 1640 | 1720 | 1750 | 1850 | 1850 | H | 1790 | 1840 | 1890 | 2000 | 2000 | 2000 | 2200 | D | 1600 | 1700 | 1830 | 1850 | 1930 | 1980 | 2500 | Test weight(KG) | 5 | 10 | 12 | 15 | 18 | 20 | 20 | Low Temp. chamber | -70C-10C ,Pre cooling time: +20C-70C , 60 min | Test. Chamber | -55C+150C | High Temp. chamber temperature | +60C+200C,Preheating time: 20 min | Transition time | 15S | Recovery time | High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample | Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample | 5 min | Ambient Temp. | +5C+35C | Power | AC 38010 50Hz ,3 phase 4 wires +Ground Wires | - - - - (3) KTS-D Series - - - - Model | - - - - KTS-D Series | - - - - | 72D | 100D | 150D | 200D | 252D | 300D | 480D | Inside size(mm) | W | 450 | 500 | 600 | 670 | 700 | 800 | 800 | H | 400 | 450 | 500 | 600 | 600 | 600 | 800 | D | 400 | 450 | 500 | 500 | 600 | 650 | 750 | Outside size(mm) | W | 1490 | 1540 | 1640 | 1720 | 1750 | 1850 | 1850 | H | 1790 | 1840 | 1890 | 2000 | 2000 | 2000 | 2200 | D | 1600 | 1700 | 1830 | 1850 | 1930 | 1980 | 2500 | Test weight | 5 | 10 | 12 | 15 | 18 | 20 | 20 | Low Temp Chamber | -80C-10C, Pre cooling time: 60 min from +20Cto-80C | Test Chamber | -65C+150C | High Temp Chamber | +60C+200C ,Within 20 min, Pre-heating time | Transition time | 15S | Recovery time | High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample | Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample | 5 min | Ambient Temp. | +5C+35C | Power | AC 38010 50Hz ,3 phase 4 wires +Ground Wires | - - - - 4. Features of Different Cooling Mode for thermal shock chambers: Since the cold chamber need huge cooling capacity for shocking, the chambers cooling mode is often designed as air-cooled or water-cooled. Air-cooled type need installation environment: The room must be equipped with exhauster and air conditioner to make sure heat dissipation timely. Its applied to small power products and cool areas. Water-cooled type need installation conditions: The customer must prepare water pipe and water tower (located outside) accordingly. The water must be pure, or it will block the pipes and result in some maintenance trouble with time going. Its often applied to large system with the features of better heat dissipation, longer service time, low noise but slightly higher price if count the fee of water tower and water pipes.

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea