Quick Detail
Place of Origin
Brand Name
HD BOILER
Model Number
Sprial fins economizer
HS-CODE
83-
Package & Delivery Lead Time
Package
Seaworthy Packing
Delivery Lead Time
60 days
Detailed Description
A335 P9 / SA 335 p22 ASTM Standard 6 inches diameter sprial welding
Introduction
1)Boiler economizers are heat exchange devices with finned tubes that heat a liquid, sometimes water, up to however sometimes doesn't exceed the boiling purpose of liquid.
2)We can manufacture three types of boiler economizer, bare tube economizer, H finned tube economizer and spiral finned tube economizer.
3)H-finned tube economizer is high efficient heat exchanger economizer which is consisted of H-finned tubes.
4)Compared with bare tube economizer, H-finned tube economizer can enlarge the heat exchange area and reduce the number of tubes.
5)It also can increase the flue gas flow area in order to reduce the flue gas flow speed and abrasion.
H-finned tube can be made as double H finned tubes , with high rigidness to fit long tube row.
6)The spiral finned economizer is a newly designed heat transfer equipment, consists of spiral fin tubes to overcome the serious abrasion and short service time.
Specifications
- - - -
Description | Boiler economizer |
Material | Alloy steel, Carbon steel, SA210C ,SA213T22, etc. |
Material standard | ASTM, EN or ISO etc. |
Dimension | Customization |
Weight | Min: 10 ton Max.:1000 ton |
Smelting Process: | EF+LF + VD |
Process | MaterialIngot Hot/Cold-Rolling Heat treatment (Normalizing+ tempering) Inspection rough machiningUT 2nd Heat treatment finishing machining Inspection |
UT standard | ASTM A388 or EN10228, etc |
- - - -
Quality Control
1. Impact test and Strength calculation report with applied materials information.
2. 100%NDT(non-destructive inspection) report of steel plate, tube and electrode.
3. X-ray, -ray and liquid penetrant test inspection report (welding seam): to ensure the quality of the entire boiler.
4. Hydraulic test report: ensure the standard working pressure and safety.
Company profile
- - - -
1 | Fabrication area of 400,000 square meters |
2 | 150 Engineers |
3 | 600 Coded welders |
4 | 60 Licensed Inspectors(NDT Level-III instructors) |
5 | Class-A Licenses for Design and Manufacture Boiler |
6 | ISO 9001:2008 Quality System |
7 | ASME Certificate of Power Boilers |
8 | ASME 'S','U' and NB stamp authorization |
- - - -