Detailed Description
Many office workers when operating the copier, are following this situation occurred. In the preheating time of the fixing roller of the copying machine, if the temperature reaches or exceeds the set temperature, fixing temperature abnormality occurs fault code on the display screen on the copier,Then the copier to stop warming. In order to prevent the fixing temperature is too high can not control, causing the upper and lower fixing roller deformation, the failure code can not be used to restart the copier method to eliminate, we only have to remove the hardware failure or replace the fixing unit to enter the warm-up process.
Here we come to introduce how to lift the fixing failure method.
1.NP3100. 3200. 3300.2020 and other models
The fault code is shown in Table
1.Remove the steps: Remove the side of the paper under the small cover, press the button inside the switch, then the display will appear OFF, and then turn off the power after 5S boot, fault code release. 
 
error code cause of issue
E000 When the printer is turned on within 1 minute, the thermistor detects the hardware temperature<100 ° C
E001 After the copier is turned on, the thermistor detects the fixing roller temperature> 200 ℃  
E004 After the copy is turned on,  the system detects the fuser roller thermistor off 3S, and the SSR turns  on the output continuously> 3S
2 .NP-7163/7214/7164 model
Fault code see Table II,
Release steps:
1, press the user key.
2, while pressing the number keys 2,8 to maintain more than 0.5S.
3, press the user key, the number screen "1".
4, press the number key "4" to display the hundred position.
5, press the AE key display screen display 3 digits, hundreds of flashing, ten and a bit bright spot.
6, press the number keys to enter 12, digital display "412".
7, press the copy button to confirm the clear.
8, shut down to restart the power, fault code release.
 