Type |
WT-H 80A |
WT-H 150A |
WT-H 416A |
WT-H 800A |
WT-H 80B |
WT-H 150B |
WT-H 416B |
WT-H 800B |
WT-H 80C |
WT-H 150C |
WT-H 416C |
WT-H 800C |
WT-H 150D |
AHL -416D |
WT-H 800D |
||||||||
Inside Dimension mm |
W |
400 |
500 |
700 |
1000 |
400 |
500 |
700 |
1000 |
400 |
500 |
700 |
1000 |
500 |
700 |
1000 |
|||||||
H |
500 |
600 |
850 |
1000 |
500 |
600 |
850 |
1000 |
500 |
600 |
850 |
1000 |
600 |
850 |
1000 |
||||||||
D |
400 |
500 |
700 |
800 |
400 |
500 |
700 |
800 |
400 |
500 |
700 |
800 |
500 |
700 |
800 |
||||||||
Outside Dimension mm |
W |
930 |
1030 |
1230 |
1530 |
930 |
1030 |
1230 |
1530 |
930 |
1030 |
1230 |
1530 |
1030 |
1230 |
1530 |
|||||||
H |
1310 |
1410 |
1660 |
1810 |
1310 |
1410 |
1660 |
1810 |
1310 |
1410 |
1660 |
1810 |
1410 |
1660 |
1810 |
||||||||
D |
810 |
910 |
1210 |
1310 |
810 |
910 |
1210 |
1310 |
810 |
910 |
1210 |
1310 |
910 |
1210 |
1310 |
||||||||
Volume L |
80 |
150 |
416 |
800 |
80 |
150 |
416 |
800 |
80 |
150 |
416 |
800 |
150 |
416 |
800 |
||||||||
Temperature range |
0℃~100℃(150℃) |
-20℃~100℃(150℃) |
-40℃~100℃(150℃) |
-70℃~100℃(150℃) |
|||||||||||||||||||
The evenness of Humiture distribution |
±0.5℃ ±3%RH |
±1℃ ±5% |
±0.5℃ ±3%RH |
±1℃ ±5% |
±0.5℃ ±3%RH |
±1℃ ±5% |
±0.5℃ ±3%RH |
±1℃ ±5% |
|||||||||||||||
Temperature rising speed |
0℃~100℃about20min |
-20℃~100℃about35min |
-40℃~100℃about40min |
-70℃~100℃about60min |
|||||||||||||||||||
Temperature falling speed |
20℃~0℃about20min |
20℃~-20℃about45min |
20℃~-40℃about60min |
20℃~-70℃about90min |
|||||||||||||||||||
Freezing system |
one-dimensional fully sealed air cooling system |
two-dimensional fully sealed air cooling system |
three-dimensional fullysealed air cooling system |
||||||||||||||||||||
Humidity range |
20%~99%RH |
humiture stability |
±0.2℃ ±2%RH |
||||||||||||||||||||
Humiture adjustment |
the modes of balancing temperature and humidity adjustment |
outside materials |
stainless steel sus # 304 |
||||||||||||||||||||
Inside materials |
stainless steel sus # 304 |
humidifying system |
surface evaporation, humidifier with stainless steel heating and equipped with a power off device when humidifier wants water and an over-temperature protection device. |
||||||||||||||||||||
Thermal material |
heat preserved by rock wool and hardened pu foaming |
heating system |
heater with stainless steel dissipation |
||||||||||||||||||||
Circulatory system |
convection by fan forced circulatory system |
dehumidifying system |
freezing dehumidifying system |
||||||||||||||||||||
Water supplying system |
The advance water tank, fully automatic water supplying control, device for reuse through recovery and circulatory filtering plus a warning device for insufficient water. |
||||||||||||||||||||||
Safety devices |
leakage and overload protection device, compressor overload protection device, power off device for over-temperature and over humidity, water insufficient protection device, over-temperature protection device for humidifier and the protection device for limit of temperature. |
||||||||||||||||||||||
Standard accessories |
Two sets of the adjustable SS plate, the vacuum glass windows, the test hole, a lamp inside the operation room and a movable indicator. |
||||||||||||||||||||||
Options |
Recorder |
Power |
AC220V、1PH、50/60HZ |