Used conveniently water cooling chiller from China

본문 바로가기


Home > Product > Used conveniently water cooling chiller from China
Product
Used conveniently water cooling chiller from China
Posting date : Jul 17, 2017
Membership
Free Member Scince Oct 19, 2016
FOB Price
$1000~$100000
Min. Order Quantity
1 set
Supply Abillity
200 sets per month
Port
Shanghai
Payment Terms
T/T
Package
standard wooden case
Keyword :
Category
Contact
Lisa
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
LNEYA
HS-CODE
8411-91
Package & Delivery Lead Time
Package
standard wooden case
Detailed Description

Reactor Systems AutoclavesPilot SystemsDouble wall reactorsAdvanced-Flow ReactorsMaterial TestingSemiconductor IndustryVacuum Chambers

Advantages & Functions

Working temperatures from -100℃ to +350℃

Intelligent temp. controlMax. process stabilityPlate heat exchager

Closed systemTouch screen displayWarning and safety functionsRapid cooling

Magnetic drive pump

Structure design

 

 

A fully closed piping design, high efficiency plate heat exchanger used to reduce the 

demand for the thermal fluid utilization while providing the system to achieve the rapid

ups and downs in temperature.

Display funcation

Displays various information on the touch screen.

Process Control Schematic diagram

High repetative of tempeature control effect 

Each cycle curve slope is consistent and greatly improve the consistency of production thermostatically control environment.

Technical Parameters:

 

Model

SUNDI-10A15W

SUNDI-10A25W

SUNDI-10A38W

Temperature range ℃

-90℃~250℃

Controller

Feed forward PID +Our special dynamic control calculation, PLC controller

Communication

MODBUS RTU Protocol, RS 485 Interface

Temp. control

Process temperature control mode

Program Editor

20 programs, each program can edit 45 steps.

Temperature feedback

Heat-conducting medium feedback PT100, (oil outlet temperature,

oil inlet temperature and heater temperature) ,Three temperature measuring points.

Process Temperature

feedback

Raw material process feedback PT100 or 4~20mA input (optional)

Process Temp. accuracy

±1℃

±1℃

±1℃

Heating power

15kW

25kW

38kW

Cooling capacity

250℃

15kW

25kW

38kW

100℃

15kW

25kW

38kW

20℃

15kW

25kW

38kW

-20℃

15kW

25kW

38kW

-40℃

15kW

25kW

38kW

-60℃

9kW

15kW

22.8kW

-80℃

5kW

8kW

12.5kW

-90℃

3kW

4.8kW

7.5kW

Circulation pump

Max110L/min

2.5BAR

Max150L/min

2.5BAR

Max250L/min

2.5BAR

Compressor

Bock

Bock

Bock

Evaporator

KAORI Plate heat exchanger

Oil separator

Emerson

Expansion valve

Emerson

Operation panel

Optional 7-inch color touch screen controller, temperature curve record, data export to excel format.

Safety protection

Self-diagnosis function; freezer overload protection; high pressure switch,

overload relay, thermal protection device, liquid low level protection,

high temperature protection and temperature fault protection.

Closedcirculation system

The whole system is full closed circulation, there is no oil mist at high temperature

and no water vapor at low temperature, pressure do not rise up when system is running.

The system will supplement oil automatically at low temperature.

Refrigerant

R-404A R23 R14 mixed Refrigerant

Connection size

DN25 PN10

DN32 PN10

DN40 PN10

 

Water-cooled type W

(cooling water at 25℃)

 

12m³/h

1.5bar~4bar

20m³/h

1.5bar~4bar

30m³/h

1.5bar~4bar

water-cooled condenser

Shell and tube exchanger(standard)

Dimension

2000*1000*1750

2300*1450*1750

2300*1450*1750

Weight

950kg

1300kg

1700kg

Power

AC380V 50HZ

34kW (max)

AC380V 50HZ

53kW (max)

AC380V 50HZ

75kW (max)

Case material

SUS 304

SUS 304

SUS 304

Optional

Optional Ethernet interface, configure the computer operating software

Optional

Water condenser use plate heat exchanger (request for high quality water)

Optional power

440V~480V 60HZ three-phase

    

Company Information

 

Development history

2006 Start production of refrigeration and heating system .

2008  The first generation of refrigeration and dynamic temperature control system.

2009 Developed the second generation of refrigeration and heating thermostat.

2010 Established WUXI GUANYA REFRIGERATION TECHNOLOGY CO., LTD.

2012 Single compressor having multiple circulation systems is applied SUNDI and LT series.

2014  Developed with large capacity of ultra-low temperature freezer

2016   low temperature freezer, plate freezer into the market

 

Packaging & Shipping

 

FAQ

 MU{0NJP$TY4V10UWX9C4_UU.png

Contact:
 
Alice Gu
TEL:86-510-82303781
WUXI GUANYA REFRIGERATION TECHNOLOGY CO.,LTD.
http://www.cnzlj.cc
 

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top