Liquid turbine flow meter/4-20mA signal output/Metering water/304 Full stainless steel material/battery powered

본문 바로가기


Home > Product > Liquid turbine flow meter/4-20mA signal output/Metering water/304 Full stainless steel material/battery powered
Product
Liquid turbine flow meter/4-20mA signal output/Metering water/304 Full...
Posting date : Nov 29, 2016
Membership
Free Member Scince Nov 11, 2016
FOB Price
negotiation
Min. Order Quantity
negotiation
Supply Abillity
negotiation
Port
negotiation
Payment Terms
negotiation
Package
negotiation
Keyword :
Category
Contact
Shusheng Li
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
dgyibiao
HS-CODE
9026-
Package & Delivery Lead Time
Package
negotiation
Detailed Description
Liquid turbine flow meter/4-20mA signal output/Metering water/304 Full stainless steel material/battery powered/low price high quality good service hot sale/China supplier/manufacturer/factory
1 General Introduction
 LW turbine flow meter is one of the most ideal liquid flow meters, which have absorbed the foreign advanced technology by our company. It has such good features: simple structure, high precision, long operating life, easy operation and repair. These products have been widely metallurgy, chemical industry, petrochemicals, city constructing and environmental protecting, and foodstuffs and other industries Favor, and to measure the liquid volume-displacement of water, tap water, sewage, diesel fuel, gasoline and low viscosity base oil.
2 Main technical parameters
2.1 Flow meter specification, basic parameters and performance index(Table 1)
2.2 Sensor precision: ±0.5%;±1%
2.3 Operating condition:
a、Ambient temperature: -20℃~+50℃
b、Medium temperature:5%~95%
c、Mixing ratio:
2.4 Electrical specification index
a、Filed indication(Built in lithium battery)inner power supplier, a couple of 3 volt lithium batteries in paralleling, normal working at battery voltage between 2.7-3v.When the voltage <2.7v, display under-voltage index margin, anti-detonation type.
b、Impulse output type :External power supplier+12VDC or +24VDC. Remote connected with computer collector, remote distance 250m, plain type and anti-detonation type.
C、4-20mA output type: External power supplier+24VDC (double line). Remote connected with computer collector, remote distance 500m, anti-detonation type.
d、Sub-body remote indication: External power supplier~220VAC, intelligent indicator remote connected with instrument cabinet.
E、Sub-body remote indication(with 4-20mA)output: External power supplier~220VAC, intelligent indicator remote connected with instrument cabinet, additional 4-20mA output connected with computer.
 
Technical parameters:Appendix Table.1
Type
Normal flow capacity
m3/h
Lower limit extended range m3/h
Operation pressure
MPa
G Operation pressure
 MPa
Z Operation pressure
 MPa
D Operation pressure
 MPa
Nominal diameter MM
LW—4
0.04-0.25
 
 
 
6.4
2.5
4
LW—6
0.1-0.6
 
 
 
6.4
2.5
6
LW—10
0.2-1.2
 
25
25
 
2.5
10
LW—15
0.7-6
0.6-6
32
32
6.4
2.5
15
LW—20
0.7-8
0.6-8
25
25
6.4
2.5
20
LW—25
1.2-10
1-10
50 25
50
6.4
2.5
25
LW—40
2.5-20
2-20
50 25
50
6.4
2.5
40
LW—50
5-40
4-40
50 2.5
50
6.4
2.5
50
LW—65
7-70
7-70
2.5
 
6.4
2.5
65
LW—80
12-100
10-100
32 2.5
32
6.4
2.5
80
LW—100
25-200
20-200
32 2.5
 
6.4
2.5
100
LW—125
30-300
30-300
2.5
 
 
2.5
125
LW—150
50-400
40-400
2.5 1.6
 
6.4
2.5
150
LW—200
100-800
80-800
2.5 1.6 
 
6.4
2.5
200
LW—250
150-1200
120-1200
2.5 1.6
 
6.4
2.5
150
LW—300
300-2500
250-2500
1.6
 
6.4
2.5
300
 
 
 
Thread connection
Nominal diameter(mm)
Nominal
pressure(MPa)
L
H
Thread
4
1.6~4.0
430
265
ZG3/8
6
1.6~4.0
430
265
ZG3/8
10
1.6~4.0
70
265
ZG1/2
15
1.6~4.0
75
265
ZG3/4
20
1.6~4.0
90
270
ZG1
25
1.6~4.0
110
275
ZG11/4
32
1.6~4.0
140
280
ZG11/2
40
1.6~4.0
140
280
ZG2
 
 
 
Conduct
 pipe connection
Nominal diameter(mm)
Nominal
pressure(MPa)
L
H
 
6
32
170
265
10
16
219
265
32
270
15
16
290
265
32
270
20
16
200
270
32
320
25
16
350
275
32
400
32
16
480
280
32
480
40
16
560
280
32
480
 
 
 
 
 
 
 
  
Low pressure flange connection
Nominal diameter(mm)
Nominal
pressure
(MPa)
L
L1
H
D
D1
n-d
15
1.6~4.0
100
132
265
95
65
4-Φ14
20
1.6~4.0
110
146
270
105
75
4-Φ14
25
1.6~4.0
120
156
275
115
85
4-Φ14
32
1.6~4.0
160
200
278
135
100
4-Φ18
40
1.6~4.0
168
208
280
145
110
4-Φ18
50
1.6~4.0
186
230
285
160
125
4-Φ18
65
1.6~4.0
200
248
293
180
145
8-Φ18
80
1.6~4.0
200
252
300
195
160
8-Φ18
100
1.6
220
272
310
215
180
8-Φ18
2.5~4.0
230
190
8-Φ22
125
1.6
250
300
325
245
210
8-Φ18
2.5~4.0
270
220
8-Φ26
150
1.6
300
360
335
280
240
8-Φ22
2.5~4.0
300
250
8-Φ26
200
1.6
360
425
360
335
295
12-Φ22
2.5
360
310
12-Φ26
4.0
375
320
12-Φ30
250
1.6
420
480
375
405
355
12-Φ26
2.5
425
370
12-Φ30
4.0
445
385
12-Φ33
300
1.6
432
502
415
460
410
12-Φ26
2.5
485
430
12-Φ30
4.0
530
460
12-Φ36
 
 
 
Intermediate-pressure flange connection
Nominal diameter(mm)
Nominal pressure(MPa)
L
L1
H
D
D1
n-d
25
6.3
130
230
270
135
100
4-Φ18
32
6.3
160
270
278
150
110
4-Φ23
40
6.3
168
290
280
165
125
4-Φ23
50
6.3
194
305
285
175
135
4-Φ23
65
6.3
206
325
293
200
160
8-Φ23
80
6.3
206
325
300
210
170
8-Φ23
100
6.3
230
360
310
250
200
8-Φ25
125
6.3
260
395
325
295
240
8-Φ30
150
6.3
310
460
335
340
280
8-Φ33
200
6.3
370
555
360
405
345
12-Φ33
250
6.3
430
630
375
470
400
12-Φ36
300
6.3
440
660
415
530
460
16-Φ36
 
High pressure flange connection
Nominal diameter
(mm)
Nominal pressure
(MPa)
L
L1
H
D
D1
n-d
25
16~26
260
160
275
160
108
4-Φ26
42
325
32
16~26
280
180
278
185
130
4-Φ26
42
345
4-Φ29.5
40
16~26
310
200
280
205
146
4-Φ29.5
42
410
4-Φ32.5
50
16~26
340
200
285
235
171.5
8-Φ26
42
430
220
8-Φ29.5
65
16~26
350
220
293
245
190.5
8-Φ29.5
42
460
250
8-Φ32.5
80
16
380
250
300
305
228.5
8-Φ26
26
8-Φ32.5
42
480
280
8-Φ35.5
100
16
460
260
310
310
241.5
8-Φ32.5
26
8-Φ35.5
42
635
350
8-Φ42
150
10
530
310
335
355
292
12-Φ29.5
                       
 
6 Impulse output type
  There are two kinds of impulse output type turbine flow meter sensor: plain type and nonexclusive type.
6.1 Main technical parameters
a、 Operation voltage:+12VDEC or +24VDEC (Consumer need to choose one power supply).
b、 Signal transmission distance: < 250m.
c、 Output signal:Square wave
d、 Amplitude: Supply amplitude of +12VDEC approximate to 10v.
Supply amplitude of +24VDEC approximate to 20v.
e、Installation: Connection of Amplifier and turbine flow meter sensor is thread m16X1.5,Having installed the turbine flow meter sensor ,wring amplifier on turbine flow meter sensor , when feel the amplifier arrive at the bottom, fix the safety nut.
f、wiring
  There are three wiring for impulse output amplifier: Red, white and shielding. Red connected to positive power supply, white connected to impulse output and other indicators or related instruments.
Notice: Make sure all wiring have been completed and be right. No connection inverted, or else it is easy to break amplifier board.
7 4-20mA output type
Main technical parameters:
a、 Operation voltage: +12VDC from external supply.
b、 Output signal:4-20Ma or 1-5V, 4mA corresponded with zero flow capacity of turbine flow meter, 20mA corresponded with maximum flow capacity, the range can be read on the namespace of turbine flow meter sensor.
c、 Signal transmission distance: < 250m.
d、Installation: Having installed the turbine flow meter sensor, wring amplifier on turbine flow meter sensor juncture (thread m16×1.5), when feel the amplifier arrive at the bottom, fix the safety nut.
e、wiring
  The external connected wires for 1-20mA impulse output amplifier are red and white.
connecting method:     +24VDC(Red wire)
 
       
     
              Grounding
8 Operation instruction of filed indication (Built in lithium battery) type
This intelligent flow meter is a new type which applies advanced Single Chip Micyoco technique combined with flow meter (turbine, vortices and so on).It indicates the instantaneous and accumulative flow capacity.
8.1 Features
a、Quite convenient to operate, input the instrument coefficient K by 4 keys on forward panel, and it indicates 6 units of  instantaneous flow capacity and 10 units of accumulative flow capacity. The first line indicates instance capacity, and the second line indicates cumulative capacity.
b、Apply EEPROM technique to store instantaneous and accumulative flow capacity.
8.2 Technical performance index
a、Accumulative capacity: Ten numbers, 4 abaft radix point, precise to per milliliter.
b、Instantaneous capacity: Six numbers, be capable of indicating the per liter change.
c、Indication precision: ±1 indication unit.
d、Signal output: Impulse output:0-5000HZ, external power supply +24VDC.
 