Main Technical Parameters
Nominal diameter: 250mm and 40,60,100,150,200
Accuracy class: 40,60mm ± 2.5% (up to ± 1.6%), 100,150,200 and 250mm ± 1.6% (up to ± 1.0%)
Measuring range: 40,60mm -0.1MPa ~ 0 ... 2.4MPa and 0 ~ 0.1 ... 60MPa
100 and 150mm -0.1MPa ~ 0 ... 2.4MPa and 0 ~ 0.1 ... 100MPa
200 and 250mm 0 ~ 0.1 ... 60MPa
Working pressure:75% of full scale under static load , 130% of full scale for over-voltage limit
Working temperature: ambient temperature -25 ~ 70 ℃ (Liquid are filled within housing), - 40 ~ 70 ℃ (Liquid is not filled within the housing)
Medium temperature: 100℃(max)
Temperature Influence: When temperature deviates from 20 ± 5 ℃, the error ≤0.4% / 10 ℃
Fluid filled: No Fill (Filling silicone oil is optional)
Load element: 316L stainless steel (<10MPa, C-shaped spring tube; ≥10MPa, spiral spring tube).
Protection: IP65
Transmission Movement: 304SS stainless steel
Housing: 304SS stainless steel, with safety explosion-proof layer and safety pressure relief back cover
Gauge Glass: Double safety explosion-proof glass
Gauge dial: aluminum white surface, black scale character
Pointer: aluminum, black
Joint: Material, 304SS or 316L thread, 40,60mm M14 × 1.5,100,150,200 250mm M20 × 1.5 and other optional standard.