Cell
|
model
|
GLP20Ah94166227
|
|
Capacity0.5C
|
25
|
||
rated voltageV
|
3.2
|
||
Typical Impedance (m)
|
1m
|
||
Battery material
|
|
||
PACK
|
Combination method
|
48
|
|
Minimal capacity0.5C
|
100
|
||
Nominal voltage
|
25.6V
|
||
Max. charge voltage
|
29.2V
|
||
Discharge cut-off voltage
|
20V
|
||
Max Charge current
|
60A
|
||
Max Working current
|
60A
|
||
Standard charge current
|
(0.2C)20A
|
||
Standard charge current
|
(0.5C)50A
|
||
Pack Impedance standard
|
5m
|
||
Weight (Approx.)
|
34Kg
|
||
Max. dimensionLWH(mm)
|
440*300*200
|
||
Operating temperature
|
Charge temperature
|
045
|
|
Discharge temperature
|
-2055
|
||
BMS
|
Single cell over-charge cut-off voltage
|
3.9
|
|
over-charge release voltage
|
3.8
|
||
Single cell under-discharge cut-off voltage
|
2.0
|
||
Discharge release voltage
|
2.3
|
||
Over-discharge cut-off current
|
260
|
||
Over-discharge cut-off current delay
|
500ms
|
||
Short-circuit protection
|
|
||
Short-circuit protection delay
|
500US
|
||
\
Condition for the recovery of over-current and Short-circuit
|
|
||
Balance current
|
180mA
|
||
Balance Condition
|
3.8
|
||
|
|