Low Power Consumption Combustible Gas Sensor NAP-50A1
Model Number: NAP-50A1
Description:
NAP-50A is a miniature & low power consumption type sensor. NAP-50A ismainly used for gas detectors. Compared to NAP-55A, NAP-50A has a loweralcohol sensitivity to eliminate false alarms caused by alcohol, thus more reliablegas detectors can be produced with NAP-50A. The following are the basiccharacteristics but it is recommended to refer to the individual user’s manual forfurther information. See NAP-66A for measuring circuit for sensor evaluation.
* Target gases and detection range
Gases | Detection range | ||
Methane | CH4 | 0.05 ~ 5% (0.05 ~ 2%) | |
Ethane | C2H6 | 0.05 ~ 3.2% (0.05 ~ 1.5%) | |
Iso-butane | Iso-C4H10 | 0.03 ~ 1.8% (0.03 ~ 0.8%) | |
Hydrogen | H2 | 0.05 ~ 4% (0.05 ~ 1.5%) | |
Hydrocarbons | CnH2n+2 | 1~100% LEL (1~50%LEL) |
* Ratings
Items | Ratings |
SupplyVoltage | DC 2.5 ± 0.25VAC 2.5 ± 0.25V (r.m.s. 50~60Hz) |
Current(When 2.0V is applied) | DC 150 ~ 170mAAC 150 ~ 170mA (r.m.s. 50~60Hz) |
AmbientTemperature | In operation -10 ~ +50℃In storage -10 ~ +50℃ |
Ambienthumidity | In operation 95%RH or lessIn storage 99%RH or less(No dew condensation) |
* Gas sensitivity characteristics
Gases & concentration | Output voltage |
Output in air | -35 ~ +35mV |
Methane 3000ppm | 10 ~ 16mV |
Iso-butane 1400ppm | 9 ~ 14mV |
Hydrogen 1400ppm | 7 ~ 12mV |
Ethanol 1% | Less than 10mV |
Drawing :
Gas sensitivity characteristics Response characteristics