Parameter
|
FWDM 4/35
|
FWDM 5/34
|
FWDM 34/5
|
|
Pass Band Wavelength Range (nm)
|
1480~1500
|
1540~1560
|
1260~1360&1480~1500
|
|
Reflection Band 1 Wavelength Range (nm)
|
1260~1360
|
1260~1360
|
1540~1560
|
|
Reflection Band 2 Wavelength Range (nm)
|
1540~1560
|
1480~1500
|
||
Insertion loss (dB)
|
Reflect Channel
|
≤0.6
|
||
Pass Channel
|
≤0.8
|
|||
Pass Band Rippler (dB)
|
<0.3
|
|||
Isolation
|
Reflect Channel
|
>15
|
||
Pass Channel
|
>30
|
|||
Insertion Loss Temperature Sensitivity (dB/℃)
|
<0.005
|
|||
Polarization Dependent Loss (dB)
|
<0.1
|
|||
Polarization Mode Dispersion (ps)
|
<0.1
|
|||
Directivity (dB)
|
>50
|
|||
Return loss (dB)
|
>50
|
|||
Maximum Power Handling (mW)
|
300
|
|||
Operating Temperature (℃)
|
-10~+75
|
|||
Storage Temperature (℃)
|
-40~+85
|
|||
Package Dimension (mm)
|
Φ5.5x34 (L38 for 900um Loose tube)
|
MWDM
|
X
|
X
|
X
|
XX
|
|
Wavelength
|
Fiber Type
|
Fiber Length
|
In/Out Connector
|
4/35=1490 pass
1310&1550 reflect
5/34=1550 pass
1310&1490 reflect
34/5=1310&1490 pass
1550 reflect
|
1=Bare fiber
2=900um loose tube
|
1=1m
2=2m
|
0=None
1=FC/APC
2=FC/PC
3=SC/APC
4=SC/PC
5=ST
6=LC
S=Specify
|