Item
项目
|
Performance性能
|
|
Jolt Test
抗震性能
|
No explosion, structural loose or damage after vibrating for 10mins in the vibration machine
震动10分钟,无爆炸、结构松散或损坏
|
|
Initiating Power
起爆能力
|
Use detonator No.4 to fire through 3mm thick lead plate, or No.8 to fire through 5mm thick lead plate, and the diameter of the hole is bigger than the out-diameter of the shell
4号雷管炸穿3毫米厚铅板,8号雷管炸穿5毫米厚铅板,穿孔直径不小于雷管外径
|
|
Oil Resistance
抗油性能
|
Immersed in 0#diesel at 75℃ under 0.3Mpa for 24hrs, put out and initiate, no misfire or incomplete explosion
浸入温度75℃、压力0.3MPa的0#柴油24小时后取出做发火试验,不应瞎火或半瞎。
|
|
Tensile抗拉性能
|
Surface Detonator地表雷管
|
Pull with 19.6N static forces for 1min, shock tube can not be pulled out
19.6N静拉力持续1分钟,导爆管无脱出
|
In-hole Detonator孔内雷管
|
Pull with 78.4 N static forces for 1min, shock tube can not be pulled out
78.4N静拉力持续1分钟,导爆管无脱出
|
|
Water resistance抗水试验
|
Surface Detonator地表雷管
|
Immersed in 1m deep water for 8hrs, performance doesn’t change
水深1米保持8小时性能不变
|
In-hole Detonator孔内雷管
|
Immersed in 30m deep water for 20hrs, performance doesn’t change
水深30米保持20小时性能不变
|
Segment
段别
|
Delay Time
延期时间
|
1
|
9ms
|
2
|
17 ms
|
3
|
25 ms
|
4
|
42 ms
|
5
|
65 ms
|
6
|
100 ms
|
7
|
150 ms
|
8
|
200 ms
|
Segments
段别
|
Delay time(ms)
延期时间
|
Segments
段别
|
Delay time(ms)
延期时间
|
1
|
25
|
16
|
400
|
2
|
50
|
17
|
425
|
3
|
75
|
18
|
450
|
4
|
100
|
19
|
475
|
5
|
125
|
20
|
500
|
6
|
150
|
21
|
550
|
7
|
175
|
22
|
600
|
8
|
200
|
23
|
650
|
9
|
225
|
24
|
700
|
10
|
250
|
25
|
750
|
11
|
275
|
26
|
800
|
12
|
300
|
27
|
850
|
13
|
325
|
28
|
900
|
14
|
350
|
29
|
950
|
15
|
375
|
30
|
1000
|