1,Overview
Piezoelectric ceramics components can be used for a wide range of industries such as modern communications, radar, sonar, automatic measurement and ultrasonic sterilization, ultrasonic power and so on.
1) PZT4 materials: Piezoelectric ceramics have a double behavior of receiving and transmitting, with higher sensitivity and lower dielectric loss.
2) PZT5 materials: Piezoelectric ceramics of receiving type have higher electro-mechanical coupling coefficient, with moderate dielectric constant and higher sensitivity.
3) PZT8 materials: Piezoelectric ceramics of high power transmitting type have good piezoelectric property, high mechanical strength, high coercive field, low dielectric loss in strong fields.
2, Dimentions
|
PZT-4
|
PZT-5
|
PZT-8
|
Piezo ceramic Discs
|
Diameter
|
3-100
|
3-100
|
3-100
|
Thickness
|
0.3-10
|
0.25-15
|
0.4-8
|
Piezo ceramic Rings
|
Outside diameter
|
3-100
|
3-100
|
3-100
|
Inside diameter
|
≥ 2
|
≥ 2
|
≥ 2
|
Thickness
|
0.3-10
|
0.25-15
|
0.4-8
|
Piezo ceramic Tubes
|
Outside diameter
|
3-108
|
3-108
|
3-105
|
Inside diameter
|
≥ 2
|
≥ 2
|
≥ 2
|
Length
|
≤50
|
≤50
|
≤50
|
Piezo ceramic Plates
|
Length
|
≤50
|
≤50
|
≤50
|
Width
|
≥ 1
|
≥ 1
|
≥ 1
|
Thickness
|
0.3-10
|
0.25-15
|
0.3-8
|
|
※ We can also design and process irregularly shaped piezoelectric ceramics.
|
|
|
|
|
3, Parameters
|
Symbol
|
PZT-4W
|
PZT-5L
|
PZT-5NL
|
PZT-5NM
|
PZT-8C
|
Electro-mechanical coupling coefficient
|
Kp
|
0.60
|
0.68
|
0.62
|
0.65
|
0.52
|
K31
|
0.33
|
0.39
|
0.36
|
0.37
|
0.30
|
K33
|
0.68
|
0.73
|
0.70
|
0.71
|
0.60
|
K15
|
0.66
|
0.72
|
0.68
|
0.70
|
0.57
|
Kt
|
0.50
|
0.55
|
0.50
|
0.53
|
0.45
|
Relative free dielectric constants
|
εTr3
|
1400
|
1700
|
2100
|
3800
|
1000
|
εTr1
|
1550
|
1730
|
2250
|
4100
|
1300
|
Piezoelectric changing constant (10-12C/N)
|
D31
|
160
|
195
|
200
|
270
|
110
|
D33
|
350
|
450
|
500
|
550
|
220
|
D15
|
500
|
650
|
680
|
700
|
350
|
Elasticity and pliancy constant (10-12m2/N)
|
SE11
|
12.6
|
17.6
|
16.7
|
18.2
|
11.1
|
SE33
|
15.8
|
19.2
|
21.5
|
23.6
|
14.9
|
Mechanical quality constant
|
Qm
|
300
|
50
|
55
|
70
|
1000
|
Frequency constant(Hz.m)
|
Nφ
|
2100
|
2000
|
2000
|
2000
|
2300
|
Nt
|
2000
|
2000
|
2000
|
2100
|
2100
|
Density(G/CM3)
|
ρ
|
7.6
|
7.6
|
7.6
|
7.6
|
7.6
|
Dielectric loss
|
tgδ
|
0.005
|
0.02
|
0.02
|
0.02
|
0.003
|
Curie temperature(℃)
|
Tc
|
300
|
320
|
320
|
280
|
300
|
|
|
※ The above data is only for reference, the exact data of piezoelectric ceramics subject to the actual test.
|
|
|