8.7-15kV(17.5) Silicone Rubber Pre-mould Indoor(Outdoor)Termination
Applications:Pre expanded indoor termination for 8.7/15(17.5)kV, single &3 core plastic insulated cable with tape/wire screen and with or without armour.
Features:Quick, easy and safe installation.High mechnical strength.Wide cross section range.Compact dimensions.Unlimited shelf life.
8.7-15kV(17.5) Silicone Rubber Pre-mould Indoor(Outdoor)Termination Technical Data 
Test sequence
Item
Requirements acc. to IEC 60502.4 
8.7/15(17.5)kV
IEC 60502.4
1
AC withstand voltage test (in air and ambient temperature)  
AC for 5 min. at 39kV. No breakdown, No flashover
PASS
2
Partial discharge
10pC max. at 15kV
PASS
3
Impulse withstand test
10 impulses of each polarity at 95kV
PASS
4
Heating cycles  in air
30 cycles at  95℃--100℃ and 22kV in air, No breakdown, No flashover
PASS
5
Heating cycles under water
30 cycles at  95℃--100℃ and 22kV under water, No breakdown, No flashover
PASS
6
Partial discharge at  95℃--100℃ 
10pC max. at 15kV
PASS
7
Thermal short-circuit (screen)
No visible deterioration at 3.0 kA, 1s
PASS
8
Thermal short-circuit (conductor)
No visible deterioration at 23.0 kA, 2s
PASS
9
Dynamic short-circuit
No visible deterioration at 81.0 kA, not less than 10 ms
PASS
10
Impulse withstand test at  95℃--100℃
10 impulses of each polarity at 95kV
PASS
11
AC withstand voltage test
AC for 15 min. at 22kV. No breakdown, No flashover
PASS
Table of specification of 8.7-15kV(17.5) Silicone Rubber Pre-mould Indoor(Outdoor)TerminationVoltage    1&3 core indoor(Outdoor)Pre-mould termination    Suit for cable Section(mm 2 )    Insulation OD of Applicable Cables8.7/15kV
I(O)CP-10/3(1).1#
35
16.2~18.2
I(O)CP-10/3(1).2#    50    17.8~19.6I(O)CP-10/3(1).3#    70    19.5~21.0I(O)CP-10/3(1).4#    95    20.5~22.5I(O)CP-10/3(1).5#    120    22.0~24.3I(O)CP-10/3(1).6#    150    23.5~25.8I(O)CP-10/3(1).7#    185    25.0~27.4I(O)CP-10/3(1).8#    240    27.0~29.5I(O)CP-10/3(1).9#    300    29.5~32.0I(O)CP-10/3(1).10#    400    32.5~34.8I(O)CP-10/3(1).11#    500    34.0~37.5

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top