45/0 Car Painting / Car Body Painting Color Analyzer Colorimeter NR145
Features:
1. Built-in white plate parameters. No need to calibrate each time which can perform measurement quickly. 2. Double Locating: Illuminating locating and precise cross locating. 3. Switchable Double Measurement End Face: Large stable end face and small concave-convex end face. 4. New 45°/0° Optical Path Design: Significantly improve the measurement stability and precision. 5. 8mm Measuring Aperture. 6. Equipped with rechargeable high-capacity Li-ion battery. No need to purchase battery repeatedly. 7. Configure CQCS3 software. Connect PC computer to realize more functions. 8. Having got SCM Metrological Certification, CE Certification, and ISO9001 Quality Management System Certification. 9. Hand-head structure: small and convenient; make the measurement easier. 10. Exquisite appearance: adopts traditional and fashionable aesthetic designs.
Specifications:
Illuminating/Viewing Geometry | 45°/0° |
Measuring Aperture | Φ8mm |
Detector | Silicon photoelectric diode |
Locating | Illuminating Locating/Cross Locating |
Measurement End Face | Large stable end-face and small concave-convex end-face |
Color Space | CIEL*a*b*C*h*,CIEL*a*b*,CIEXYZ |
Color Difference Formula | delta E*ab delta L*a*b* E*C*h* |
Light Source | D65 |
Light Source Device | LED blue light excitation |
Errors Between Each Equipment | ≤0.80 delta E*ab |
Storage | 100pcs standards 20000pcs samples |
Repeatability | Standard deviation within E*ab 0.08 Average of 30 measurements of standard white plate |
Language | English/Chinese |
Weight | 500g |
Dimension | 205×67×80 mm |
Power source | Rechargeable lithium-ion battery 3.7V@3200mAh |
Lamp Life | 5 years, more than 1.6 million measurements |
Charging Time | 8 hours--100% electricity |
PC Software | CQCS3 Software |
Printer (optional) | Miniature thermal printer |
FAQ:
1. When I received NH310/NH300 colorimeter and perform measurement, why the measured data is abnormal?
After receiving NH310/NH300, you have to perform white and black calibration manually when first starting.
2. In which condition, manual white and black calibration and auto calibration are required for NH310? a. It’s needed to perform manual calibration for NH310 when first starting.b. In the subsequent starting, NH310 will perform auto calibration at startup. No need to perform manual calibration.c. Suggestion: it’s best to perform manual calibration once a week or when NH310 measured data is not accurate.
3. In which condition, manual white and black calibration for NH300 is required?a. It’s needed to perform manual calibration for NH300 when first starting.b. In the subsequent starting, no need to perform manual calibration.c. Suggestion: it’s best to perform manual calibration once a week or when NH300 measured data is not accurate.
4. How to replace NH310 measuring aperture?There are three measuring apertures for NH310: Φ8mm (standard accessory), Φ4mm (standard accessory), extended Φ8mm (optional accessory)a. Turning onb. Removing measuring aperture, install the needed measuring aperture.c. Select “Settings-Aperture Setting” in main menu to select corresponding measuring aperture.d. After selecting aperture, the instrument will display “White and Black Calibration” interface. White and black calibration must be performed.e. Replace completed.
5. CQCS3 (Color Quality Control System) Installation
a. Before installation, please Copy CQCS3 folder to your computer and don’t remove any files in CQCS3 folder.b. Double-click the setup.exe to install CQCS3 software.c. Then double-click Install.bat under the CQCS3\USB_Driver file to install the driver.d. Detailed installation information please read the "Installing Software" under CQCS3 User manual.doc.
Warranty:
NR145 paint color analyzer Colorimeter with 45/0 is under warranty for 12 months from the purchase date. Customers must provide warranty card and valid proof of purchase.