DUK-2A 60 Channel High-resolution Research Tomography Multi-Electrode Resistivity Survey Non-metal Mineral Water Detector

본문 바로가기


Home > Product > DUK-2A 60 Channel High-resolution Research Tomography Multi-Electrode Resistivity Survey Non-metal Mineral Water Detector
Product
DUK-2A 60 Channel High-resolution Research Tomography Multi-Electrode ...
Posting date : Sep 24, 2014
Membership
Free Member Scince Sep 24, 2014
FOB Price
1-2
Min. Order Quantity
1
Supply Abillity
100/month
Port
shanghai
Payment Terms
T/T
Package
wooden case or as your requirment
Keyword :
Category
Contact
Ailee
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
GOLD
Model Number
DUk-2A
HS-CODE
9024-10
Package & Delivery Lead Time
Package
wooden case or as your requirment
Delivery Lead Time
1o days
Detailed Description

Specifications

 
the Multi-Electrode Resistivity Survey instrument is widely used in many aspects including metal and non-metal mineral resources 
 
Main Applications

 

1 Widely used for high-resolution research, tomography and monitoring applications.

2 Coal mining gobs, caves of Custer area, geological disasters survey like landslides other geological disasters.

3 High resolution engineering geological exploration like factory foundations, highways, bridges, railways, civil engineering, hydrology, engineering, environmental.

4 For landslides and other geological disaster exploration.

5 Metal and non-metallic mineral resources exploration and geothermal exploration

 

Main Features.

 

1 Assembly data acquisition devices and multiplexer together in the same case,which not only reduce the volume but also decrease the weight, thus avoid errors caused by operating the devices separately and due to inconformity of switch parameter settings.

2 Maintain all functions of DUK-2A Multi-Electrodes Resistivity Survey System and conventional electrical method.

3 Add high and low current transform taps, add high and low input impedance transformation tap, and improve the acquisition capability of weak signals.

4 Add storage and output functions for compensation SP voltage value.

5 Adopt 16-bit A/D and 16-bit D/A, thus improve the discernibility for measurement of collected data.

6 Add the function for automatically detect grounding resistance before each measurement; give directions for the points exceed the grounding resistance value, for automatically proceeding with further measurement if required; the value at such point can be replaced with a fixed symbol to facilitate the elimination of this point while processing the information and data.

7 Greatly enhance the repeatability of measured data.

 
Technical Specifications

Measuring unit ( DZD-6A)

 

1 Maximum Measuring Voltage: -6000mV~+6000mV

2 Measuring Voltage Resolution: 0.01 mV

3 Measuring Voltage Accuracy: (at Vp>10mV)±5%, ±1 digit; (at Vp<10mV)±1%, ±1 digit

4 Suppression on 50Hz Power Frequency: 80dB

5 Measuring Current: 0~5000 mA

6 Measuring Current Resolution: 0.01 mA

7 Measuring Current Accuracy: (at Ip>10mA)±5%, ±1 digit; (at Ip<10mA) ±1% ±Letter

8 Input Impedance ≥50 MΩ

9 Measured Apparent Polarizability Accuracy: ±1%, ±1 digit

10 Maximum Power Supply Voltage 900V

11 Maximum Power Supply Current: 5A

12 Power Supply Pulse Width: 1~60 sec.

13 Weight: 8 kg

14 Volume: 305×200×202mm

 

DUK-2A Multiplex Electrode Converter

 

1 Conversion Electrodes: 60 channels or 120 channels

2 Sopported manual configuration: Wenner, Schlumberger 1, Schlumberger 2, Dipole-Dipole, Combined Profiles, Differential, Pole-Pole, Triple-Pole Rolling,

3 Operating Mode: 16-key keypad with 90 character LCD display combines to form man-machine dialogue operation.

4 Maximum Allowable Current: 2A

5 Maximum Withstand Voltage: 500V DC

6 Insulating Property: 500MΩ

7 Electroshock Break-over Resistance: smaller than 0.1Ω

8 Power Consumption: 50 mA (Standby)

9 Power Supply: 1# Dry Cell (or rechargeable battery with the same specification) 8 pcs.

10 Working Temperature: -10°C~ +50°C, 95%Rh

11 Weight: 7 kg (60 channels), 7.5kg (120 channels)

12 Volume: 305×200×202mm (60 channels), 324×200×245mm (120 channels


ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top