S11 Series 6kV-35kV power Transformer With Off Circuit Tap Changer,power oill transformer,high voltage step up transformer,distribution transformer

본문 바로가기


Home > Product > S11 Series 6kV-35kV power Transformer With Off Circuit Tap Changer,power oill transformer,high voltage step up transformer,distribution transformer
Selling leads
S11 Series 6kV-35kV power Transformer With Off Circuit Tap Changer,power oill tr...
Posting date : Jul 10, 2019
Membership
Free Member Scince Feb 28, 2019
FOB Price
-
Min. Order Quantity
1piece
Supply Abillity
1000000kVA/year
Port
Tianjin,Shangshai,Ningno
Payment Terms
T/T L/C
Package
Wooden case or As customer request
Keyword :
Category
Contact
Jia Qiong
Selling Leads Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
ZYDQ
HS-CODE
8504-34
Package & Delivery Lead Time
Package
Wooden case or As customer request
Delivery Lead Time
15-20 days
Detailed Description
The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission.
Product Description
The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission.
S11 series transformer adopts high quality material for copper winding, especially applying the new technology and new material for the coil insulation and active parts, thus the no-load and the load loss are obviously reduced, the performance and structure are more reliable and superior.
 
Product Features
● Good Economic Performance
The no-load loss for S11 series products decreased 10.3% averagely, no-load current decreased 22.4% based on S9 series.
● Long Service Life
Transformer tank adopts hermetical structure, tank and tank cover can be connected by bolts or welded firmly, the transformer oil won’t contact with air, so that extend the service life effectively.
● High Operation Reliability
Improve the relevant sealing parts for the tank, increase the reliability and advance the technical level to ensure the reliability of the seal.
● Small Installation Area
S11-M series transformer tank uses the corrugated plate radiator. When the oil temperature changes, the corrugated plate will proceed thermal expansion, which can replace the role of the oil conservator. the corrugated plate tank has beautiful appearance, less occupied area. 
Table 1: 6Kv, 10kV & 30kVA-2500kVA Power Transformer With Off Circuit Tap Changer
Rated Capacity (kVA)
Voltage Combination
Connection Group Symbol
No-load Loss R(W)
Load Loss R(W)75℃
Impedance Voltage (%)
No-load Current(%)
Length L(mm)
Width W (mm)
Height H(mm)
Gauge Horizontal*Vertical(mm)
Active parts Weight(Kg)
Oil Weight(Kg)
Total Weight(Kg)
(KV) High Voltage
Tapping Range of High Voltage
(KV)Low Voltage
30
66.31010.5
±5%±2×2.5%
0.4
Dyn11Yzn11Yyn0
100
630/600
4.0
2.8
980
735
1145
400*400
178
78
355
50
130
910/870
2.5
1017
758
1205
450*400
240
92
415
63
150
1090/1040
2.4
1035
785
1285
450*400
285
105
505
80
180
1310/1250
2.2
1065
800
1290
450*400
330
110
540
100
200
1580/1500
2.1
1072
820
1305
450*400
345
116
590
125
240
1890/1800
2.0
1155
1105
1310
450*550
415
135
705
160
280
2310/2200
1.9
1235
850
1535
550*550
485
155
835
200
340
2730/2600
1.8
1282
860
1557
550*550
582
168
965
250
400
3200/3050
1.7
1310
940
1605
550*550
695
210
1135
315
480
3830/3650
1.6
1465
1120
1915
660*650
855
255
1520
400
570
4520/4300
1.5
1440
1165
1725
660*660
950
295
1590
500
680
5410/5150
1.4
1510
1250
1845
660*650
1150
320
1905
630
810
6200
1.3
1650
1140
1920
660*650
1500
435
2015
800
980
7500
4.5
1.2
2125
1175
2315
820*820
1910
760
3510
1000
1150
10300
1.1
2150
1380
2570
820*820
2125
880
3850
1250
1360
12000
1.0
2355
1485
2570
820*820
2605
960
4610
1600
1640
14500
0.9
2385
1750
2630
820*820
3125
1150
5420
2000
1940
18300
5.0
0.4
1940
1400
1700
820*820
2420
780
4200
2500
2290
21200
0.4
2050
1480
1800
820*820
2560
880
4680
Notes:
1. The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.
2. For the transformer of rated capacity up to 500kVA, the value of load loss above the oblique line in the table is applicable to the connection group Dyn11 or Yzn11. The value of load loss under the oblique line is applicable to the connection group Yyn0.
 
Technical Parameter for S11 Series 20kV Power Transformer With Off Circuit Tap Changer
Rated capacity(KVA)
Voltage Combination
Connection Group Symbol
No-load Loss(W)
Load Loss (W)75℃
No-load Current (%)
Short-circuit Impedance(%)
High Voltage (KV)
Tapping ranges of High Voltage
Low Voltage(KV)
30
20
±5% ±2×2.5%
0.4
Dyn11Yzn11Yyn0
100
690/660
2.1
5.5
50
130
1010/960
2.0
63
150
1200/1150
1.9
80
180
1440/1370
1.8
100
200
1730/1650
1.6
125
240
2080/1980
1.5
160
290
2540/2420
1.4
200
340
3000/2860
1.3
250
400
3520/3350
1.2
315
480
4210/4010
1.1
400
570
4970/4730
1.0
500
680
5940/5660
1.0
630
810
6820
0.9
6.0
800
980
8250
0.8
1000
1150
11330
0.7
1250
1380
13200
0.7
1600
1660
15950
0.6
2000
1950
19140
0.6
2500
2340
22220
0.5
Notes:
1. The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.
2. For the transformer of rated capacity up to 500kVA, the value of load loss above the oblique line in the table is applicable to the connection group Dyn11 or Yzn11. The value of load loss under the oblique line is applicable to the connection group Yyn0.
3. The performance parameters in the table are also applicable for HV with dual voltage 20 (10)kV three-phase transformer.
 
Technical Parameter for S11 Series 35kV Power Transformer With Off Circuit Tap Changer
Model
Voltage Combination
Connection Group Symbol
No-load Loss (W)75℃
Load Loss R(W)
Impedance Voltage (%)
No-load Current(%)
Length L(mm)
Width W(mm)
Height H(mm)
Gauge Horizontal*Vertical (mm)
Active parts Weight(Kg)
Oil Weight(Kg)
Total Weight(Kg)
High Voltage (kV)
Tapping Range of High Voltage %
Low Voltage (kV)
50
3538.5
±2×2.5%±5%
0.4
Dyn11/ Yyn0
160
1200/1140
6.5
1.3
1195
935
1825
660*660
300
330
860
100
230
2010/1910
1.1
1200
995
1935
660*660
470
383
1130
125
270
2370/2260
1.1
1235
940
1955
660*660
550
465
1335
160
280
2820/2680
1.0
1285
895
1950
660*660
580
485
1475
200
340
3320/3160
1.0
1310
1150
1985
660*660
680
595
1755
250
400
3950/3760
0.95
1450
1090
2010
660*660
860
650
2000
315
480
4750/4530
0.95
1930
1065
2320
820*820
980
765
2290
400
580
5740/5470
0.85
1850
1165
2015
820*820
1170
885
2725
500
680
6910/6580
0.85
2045
1205
2415
820*820
1340
960
3090
630
830
7860
0.65
2085
1240
2515
660*660
1550
895
3810
800
980
9400
0.65
2305
1615
2685
820*820
1990
1030
4510
1000
1150
11500
0.65
2545
1540
2590
1070*1070
2415
1475
5055
1250
1400
13900
0.60
2495
2010
2675
820*820
2480
1405
5290
1600
1690
16600
0.60
2680
2100
2770
820*820
2600
1490
5450
2000
1990
19700
0.55
2790
2180
2860
820*820
2720
1590
5600
2500
2360
23200
0.55
2900
2290
2980
1070*1070
2830
1720
5760
Notes:
1. The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.
2. For the transformer of rated capacity up to 500KVA, the value of load loss above the oblique line in the table is applicable to the connection group Dyn11. The value of load loss under the oblique line is applicable to the connection group Yyn0.
 
S11 Series 35kV 630kVA-31500kVA Three-phase Dual Winding Power Transformer With Off Circuit Tap Changer
Model
Voltage Combination
Connection Group Symbol
No-load Loss (W)
Load Loss R(W)
No-load Current(%)
Short circuit impedance (%)
Length L(mm)
Width W(mm)
Height H(mm)
Gauge Horizontal*Vertical (mm)
Active parts Weight(Kg)
Oil Weight(Kg)
Total Weight(Kg)
High Voltage (kV)
Tapping Range of High Voltage %
Low Voltage (kV)
630
35
±2×2.5%±5%
3.156.310.5
Yd11
830
7860
0.65
6.5
2400
1700
2210
820*820
2210
900
3250
800
980
9400
0.65
2500
1850
2390
820*820
2350
1030
3500
1000
1150
1150
0.65
2700
1950
2510
820*820
2490
1180
3860
1250
1400
1390
0.55
2900
2050
2630
820*820
2600
1350
4350
1600
1690
1660
0.45
3050
2130
2750
820*820
2810
1580
4855
2000
2170
1830
0.45
3105
2195
2805
1070*1070
2800
1800
5300
2500
2560
1960
0.45
3150
2535
2980
1070*1070
3525
2060
7665
3150
35-38.5
±2×2.5%±5%
3.156.310.5
3040
2300
0.45
7.0
3920
2725
2840
1070*1070
3995
2205
8565
4000
3610
2730
0.45
3310
2915
3070
1070*1070
4825
2560
10115
5000
4320
3130
0.45
3480
3020
3145
1070*1070
5700
2635
11305
6300
5240
3500
0.45
8.0
3590
2905
3210
1475*1475
7120
3240
13510
8000
35-38.5
±2×2.5%
3.153.36.36.610.5
YNd11
7200
3840
0.35
4070
3050
3595
1475*1475
8875
3840
16690
10000
8700
4530
0.35
4106
2795
3655
2000*1475
10305
3600
17690
12500
1000
5380
0.30
4570
3010
3840
1475*1475
12830
4310
20990
16000
1210
6580
0.30
5235
3295
4615
2000*1475
16010
6650
27660
20000
1440
7950
0.30
5360
3415
4660
2000*1475
18820
7600
32170
25000
1700
9400
0.25
10.0
5830
3810
4860
2000*1475
22360
9800
42600
31500
2020
112000
0.25
6290
4290
5260
2000*1475
25110
12010
49960
Note: 1.For the transformer of low voltage 10.5kV, the connection group symbol is applicable to Dyn11.
Note: 2.For the transformer of rated capacity 3150kVA or above, the -5% tapping position is for maximum current tap.
Note: 3.When the annual average load rate for the transformer is between 35% to 45%, the loss value in the table can obtain the highest operational efficiency.
We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you.If you want to know more about the product, please click here.
 

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top