www.tobeepump.com Tobee® 300mm 12-24m3/h vertical circulation centrifugal pump

본문 바로가기


Home > Product > www.tobeepump.com Tobee® 300mm 12-24m3/h vertical circulation centrifugal pump
Selling leads
www.tobeepump.com Tobee® 300mm 12-24m3/h vertical circulation centrifugal pump
Posting date : Aug 01, 2018
Membership
Free Member Scince May 04, 2016
FOB Price
1200sets/month
Min. Order Quantity
1set
Supply Abillity
100000sets/month
Port
Tianjin
Payment Terms
T/T
Package
Wooden case
Keyword :
Category
Contact
Donna Zhang
Selling Leads Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
Tobee
Model Number
300mm 12-24m3/h vertical circulation centrifugal pump
HS-CODE
8413-70
Package & Delivery Lead Time
Package
Wooden case
Delivery Lead Time
7days
Detailed Description
 
Size: 300mm
Capacity: 288-1267m3/h
Head: 6-33m
Speed: 350-700rpm
Eff.: 50%
Power: Max.200kw
Handling solids: 65mm
Materials: High chrome alloy, Rubber, Polyurethane, Ceramic etc 
 
 Tobee® 300mm  12-24m3/h vertical circulation centrifugal pump is unique cantilevered design, The sump pumps doesn’t need any seal and seal water. The TP300TV pumps are preferred by many customers with special installation requirements and widely applied in sump. Its wear-resistant metal liner could handle abrasive slurries with rough particles and high concentration.
 
Tobee Warman

Power P 

(kw)

Capacity Q

(m3/h)

Head H

(m)

Speed n

(r/min)

Eff. η

(%)

Impeller dia.

(mm)

Max. particles

(mm)

Weight

(kg)

TP(R)300TV 300TV-SP(R) 22--200 288-1267 6-33 350-700 50 610 65 3940
 
 
Faults Reason Removal
Pump fails to discharge any liquid. Incorrect direction of pump rota- tion and impeller worn.Suction pipe blocked Check direction of rotation and replace anew impeller
Power consumption on shaft is excessive Rotating component is rubbing on a stationary part.Bearing worn.Drive belt tension too tightFlow rate too largePump speed and ratio too high.Misalignment or unparallel of drive shaft and pump shaft. Removal the rubReplace the bearingAdjust beltModify the pump duty and speed.Adjust drive and pump shaft
Bearing is over hearing Lubricants too much or less.Containing impurities in the lubricantBearing worn. Lubricating as requirements.Replace clean lubricant.Replace new bearing.
Bearing has short life. Misalignment or unparallel of drive and pump motor.Shaft bent.Impeller unbalanced due to wearForeign object entered into the bearing or insufficient lubricationIncorrect procedure followed in fitting bearings. Adjusting drive and pump shaft.Replacing shaft.Remove rubbing and replace new impellerClean the bearing.Replace or refit the bearings.
Pump vibrates or is noisy. Bearings worn.Impeller unbalanced.Air entered into suction pipe or blocked.Flow rate is none—uniform and pump not primed. Replaced by new bearings.Replaced by new impeller.Discharge air and remove block.Improve on the pump feeding.
 

Tobee® TP300TV Sump Slurry Pumps are widely used for Mining, Mineral Processing, Sand and Gravel, Coal Prep, Chemical Slurry Service, Cyclone Feeds, Aggregate Processing, Wet crushers, SAG mill discharge, Fine Primary Mill Grinding, Tailings, Secondary Grinding, Bottom/fly ash slurries, Pulp And Paper, Food Processing, Cracking Operations, Gypsum slurries, Pipeline Transport, High Velocity Hydraulic Transport,Food Processing, Explosive Sludge In Metal Smelting, River And Pond Dredging, Heavy Refuse Removal, Larger Particle Or Low NPSHA Applications, Continuous (Snore) Sump Pump Operation, Abrasive Slurries, High Density Slurries, Large Particle Slurries, Sump Drainage, Wash down, Floor Drainage, Mixing, Iron Ore, Cooper, Diamond, Aluminum oxide, Gold, Kaolin, Phosphorite, Steel, Palm, Suger, Chemical, Power, FGD, Frac Sand Blending, Waste water, Flotation etc. 