LDG Electromagnetic Flowmeter

본문 바로가기


Home > Product > LDG Electromagnetic Flowmeter
Selling leads
LDG Electromagnetic Flowmeter
Posting date : Oct 31, 2014
Membership
Free Member Scince Oct 31, 2014
FOB Price
400-800USD/Unit
Min. Order Quantity
1
Supply Abillity
100
Port
Shanghai
Payment Terms
T/T,Western Union,L/C
Package
International Standard Wood Case
Keyword :
Category
Contact
Shingo Zhang
Selling Leads Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
Firstcon
Model Number
LDG
HS-CODE
8413-19
Package & Delivery Lead Time
Package
International Standard Wood Case
Delivery Lead Time
Within 14-30 Days After receipt of payment
Detailed Description
LDG Electromagnetic Flowmeter
 
Overview
LDG series of intelligent electromagnetic flowmeter is made according to the law of electromagnetic induction, which is used to measure the volume flow of conducting liquid in the pipe, such as water, sewage, slurry, ore pulp, acid, alkali, salt liquids and food slurry, etc. It is widely used in the industries of petrochemical, mining, coal and water conservancy which solve the drainage, sewage treatment problems.
 
Operating Principle
The electromagnetic flowmeter is based on the theory of Faraday's law of electromagnetic induction.
When a conductor cuts magnetic line of force, it will generate EMF (Electromotive Force). According to this principle, the volume of flowing conductive fluid in pipe can be measured, flowing direction of conductive fluid is perpendicular to the direction of electromagnetic field, an alternating magnetic field is applied in a direction which is perpendicular to the conduit, and install a pair of electrodes on both sides of the conduit’s inner surface which has insulated lining. When the conductive liquid goes through the conduit, both electrodes generate EMF because magnetic line of force is being cut. EMF is proportional to the flow, finally, the flow can be exported.
 
Features
1. Measurement is not influenced by the changes of liquid density, viscosity, pressure and conductivity.
2. No active and choked flow parts, no pressure loss, no blocking, measurable for the liquid with fiber, solid particles and suspended solids.
3. Reaction of the instrument is sensitive. The measuring range, the flow rate is 0.3-15m/s, conductive liquids of conductivity≥5μs/cm all can be measured, and measuring range can be selected arbitrarily.
4. The instrument uses a low-frequency three-state square-wave excitation technology, advanced small-signal processing technology and software technology, so it has the strong anti-interference, high precision, stable and reliable.
5. The instrument is not affected by the flow direction of liquid, can measure as both forward and reverse installation, and easy to install, less demanding for the straight pipeline.
6. Corrosion resistance and abrasion resistance of electrode and the lining material of electromagnetic flow meter are excellent, with a long service life. According to the special condition requirements of users, we can produce electromagnetic flowmeters, for example, electromagnetic flowmeter of submerged type.
7. Impact resistance and vibration resistance of the instrument are excellent.
8. Not measurable for gas and non-conducting liquids.
 
Main Technical Parameters
Flow Measurement Range and Turndown Ratio
Display turndown ratio 1: 150, Accuracy turndown ratio Grade 0.3  1: 4, Grade 0.5  1: 10, Grade 1.0  1: 20
Velocity range
0.3~15m/s
Medium conductivity
≥5μs/cm
Measurement Accuracy
Grade 0.3, Grade 0.5, Grade 1.0
Medium Temperature
-20℃~60℃, -20℃~90℃, -20℃~100℃, -20℃~180℃
Pressure
1.6, 2.5, 6.4, 16, 26, 42Mpa
Operating Environment
Temperature -20℃~+50℃ Humidity≤85%, Air pressure 86kpa~106kpa
Output Signal
Frequency output 0-5KHz  Voltage output 1-5V
Current output 4~20mA, RS-485 serial interface or RS232 interface, Mudbus protocol
Hart protocol
Data storage time for outage
 
10 years
Power supply
①Outer supply 220VAC±15%; ②Outer supply 24VDC±5% (Optional) ③Lithium battery power supply
Power Dissipation
≤15w (Outer power supply)
Protection Level
IP67, IP68 (Only adapt to the separated type)
Lining Material
Polyurethane rubber, Chloroprene rubber, Polytetrafluoroethylene, F46 and so on.
Electrode Material
316L, Hastelloy HB, Hastelloy HC, Titanium, Platinum and so on.
Special Electrode Material
For example: Titanium, Tantalum, Platinum and other rare metal materials
Installing Type
Integrated type, Separated type (wall mounting type)
Explosion-proof Level
ExmdibIIBT4
 
Flow Range
Inner diameter (mm)
10
15
20
25
32
40
50
65
Qmin (m3/h)
Qmax (m3/h)
0.0283
4.24
0.0636
9.54
0.12
16.96
0.176
26.5
0.29
43.42
0.452
67.85
0.7
106.0
1.19
179.0
Inner diameter (mm)
80
100
125
150
200
250
300
350
Qmin (m3/h)
Qmax (m3/h)
1.8
271.0
2.82
424.0
4.41
662.0
6.36
954.0
11.3
1690
17.6
265.0
25.4
381.0
34.6
5190
Inner diameter (mm)
400
450
500
550
600
700
800
900
Qmin (m3/h)
Qmax (m3/h)
45.2
6780
57.2
8570
77.6
10600
85.5
12800
101.0
15200
138.0
20700
180.0
27100
229.0
34300
Inner diameter (mm)
1000
1100
1200
1400
1600
1800
2000
2200
Qmin (m3/h)
Qmax (m3/h)
282.0
42400
342.0
51300
407
61000
554.1
83121
732.7
108566
916.0
137404
1131.0
169635
1368.4
205258
 
Flow Range
Inner diameter (mm)
10
15
20
25
32
40
50
65
Qmin (m3/h)
Qmax(m3/h)
0.0283
4.24
0.0636
9.54
0.12
16.96
0.176
26.5
0.29
43.42
0.452
67.85
0.7
106.0
1.19
179.0
Inner diameter (mm)
80
100
125
150
200
250
300
350
Qmin (m3/h)
Qmax(m3/h)
1.8
271.0
2.82
424.0
4.41
662.0
6.36
954.0
11.3
1690
17.6
265.0
25.4
381.0
34.6
5190
Inner diameter (mm)
400
450
500
550
600
700
800
900
Qmin (m3/h)
Qmax(m3/h)
45.2
6780
57.2
8570
77.6
10600
85.5
12800
101.0
15200
138.0
20700
180.0
27100
229.0
34300
Inner diameter (mm)
1000
1100
1200
1400
1600
1800
2000
2200
Qmin (m3/h)
Qmax(m3/h)
282.0
42400
342.0
51300
407
61000
554.1
83121
732.7
108566
916.0
137404
1131.0
169635
1368.4
205258
 

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top