Packaging Details: | Packaging individual packing and standard export carton LXC620 Completely replaced dse720 ats generator control module |
---|---|
Delivery Detail: | In stock |
* Note: If the contents mentioned other manufacturers's names and models, the narrative only for informational purposes, this product is not original, but it can compatible with them.
LXC620 Completely replaced dse720 ats generator control module
Photos---------
Description----------
The LXC610/620 is used in single machine automation, which can control the Genset starting by remote boot signal
The LXC620 added the function is based in LX610, which is automatic mains failure control module. can monitor a mains supply and automatically start.
Working voltage DC8.0V to 35.0V (continue to supply)
Consumer power <3W (stand model: ≤2W )
Alternator Input voltage:
12V AC - 360 V AC (ph-N) 3 Phase 4wire
23V AC - 620 V AC (ph-ph) 3 Phase 3wire
12V AC - 360 V AC (ph-N)
12V AC - 360 V AC (ph-N)
Frequency 50/60HZ
Speed sensor voltage Vpp: 1.0 - 70Vpp
Speed sensor Frequency: Max 10000HZ
Starting relay output: 10Amp DC28V
Fuel relay output : 10Amp DC28V
Programmable relay output 1: 10Amp DC28V
Programmable relay output 2: 10Amp DC28V
Power switching programmable relay output 3: 10Amp 250VAC
Mains switch relay programmable relay output 4: 10Amp 250VAC
Out Size: 209mm x 146mm x 26mm
Tapping Size: 214mm x 160mm
Current transformer secondary electric 5A
Working condition: Temp. (-25~+70)°C humidity (20~90)%
Storage condition: Temp. (-25~+70)°C
Weight: 0.56kg
Power Supply | 8 to 35 Vdc Continuous |
Cranking Dropouts: | Able to survive 0 V for 50mS, providing supply was at least 10V before dropout and supply recovers to 5V without the need for internal batteries. |
Max Current | Operating 320mA at 12V, 215mA at 24V; Standby 175mA at 12V, 95mA at 24V |
Start Relay Output: | 16 Amp DC at supply voltage. |
Fuel Relay Output: | 16 Amp DC at supply voltage. |
Auxiliary Relay Outputs: | 5 Amp DC at supply voltage. |
Charge Fail / Excitation Range | 0 V to 35 V |
Alternator Input Range: | 15V(ph-N) to 300V(ph-N) 3 Phase 4wire AC (+20%) |
Alternator Input Frequency: | 50 - 60 Hz at rated engine speed (Minimum: 15V AC Ph-N) |
Mains Supply Input Range: | 15V(ph-N) to 300(ph-N) 3 Phase 4wire AC (+20%) |
Mains Supply Input Frequency: | 50 - 60 Hz at rated engine speed (Minimum: 15V AC Ph-N) |
Magnetic Pick-up Voltage Input Range: | +/- 0.5 V to 70 V Peak |
Magnetic Input Frequency: | 10,000 Hz (max) at rated engine speed |
Operating Temperature Range: | -30 to +70°C |
Panel Cutout: | 220mm x 160mm ( 8.7" x 6.3" |
Starting Controller Series ---------
Usage |
* Biogas Power Generation |
*Natural Gas Power |
*Field Engineering |
*Electric Power |
*Factory |
*Fire-fighting |